[86414191] (b)(4). (b)(6).
Patient Sequence No: 1, Text Type: N, H10


[86414194] The customer experienced an issue where the elecsys free psa immunoassay results were higher than the elecsys total psa immunoassay results for one patient. The customer used cobas e 411 (disk) immunoassay analyzer (b)(4). The free psa result was 3. 36 ng/ml and the total psa result was 0. 319 ng/ml. The sample was tested in another laboratory by clia. The free psa result was 0. 17 ng/ml and the total psa result was 1. 17 ng/ml. A second sample was taken from the patient on (b)(6) 2017. The free psa result was 3. 81 ng/ml and the total psa result was 0. 313 ng/ml. The second sample was tested in another laboratory on another cobas e 411 immunoassay analyzer. The serial number of this analyzer was not provided. The free psa result was 3. 40 ng/ml and the total psa result was 0. 33 ng/ml. The results were reported outside of the laboratory. There was no allegation of an adverse event. (b)(6).
Patient Sequence No: 1, Text Type: D, B5


MAUDE Entry Details

Report Number1823260-2017-01997
MDR Report Key6867973
Report SourceFOREIGN,HEALTH PROFESSIONAL,U
Date Received2017-09-15
Date of Report2017-12-17
Date of Event2017-08-01
Date Mfgr Received2017-08-27
Date Added to Maude2017-09-15
Event Key0
Report Source CodeManufacturer report
Manufacturer LinkY
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag3
Health Professional3
Initial Report to FDA3
Report to FDA3
Event Location3
Manufacturer ContactNA MICHAEL LESLIE
Manufacturer Street9115 HAGUE ROAD NA
Manufacturer CityINDIANAPOLIS IN 46250
Manufacturer CountryUS
Manufacturer Postal46250
Manufacturer Phone3175214343
Manufacturer G1ROCHE DIAGNOSTICS GMBH
Manufacturer StreetSANDHOFERSTRASSE 116 NA
Manufacturer CityMANNHEIM (BADEN-WURTTEMBERG) 68305
Manufacturer CountryGM
Manufacturer Postal Code68305
Single Use3
Previous Use Code3
Removal Correction NumberNA
Event Type3
Type of Report3

Device Details

Brand NameFREE PSA
Generic NameTEST,PROSTATE SPECIFIC ANTIGEN,FREE,(NONCOMPLEXED) TO DISTINGUISH PROSTATE CA
Product CodeMTG
Date Received2017-09-15
Model NumberNA
Catalog Number03289788190
Lot Number20987702
ID NumberNA
Device Expiration Date2018-05-31
OperatorHEALTH PROFESSIONAL
Device AvailabilityN
Device AgeDA
Device Eval'ed by MfgrR
Device Sequence No1
Device Event Key0
ManufacturerROCHE DIAGNOSTICS
Manufacturer Address9115 HAGUE ROAD NA INDIANAPOLIS IN 462500457 US 462500457


Patients

Patient NumberTreatmentOutcomeDate
10 2017-09-15

© 2026 FDA.report
This site is not affiliated with or endorsed by the FDA.