ABL700SERIES AND ABL800SERIES ABL825 *

MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed from a 01 report with the FDA on 2006-04-10 for ABL700SERIES AND ABL800SERIES ABL825 * manufactured by Radiometer Medical Aps.

Event Text Entries

[450865] It is possible for the abl 700 analyzer to make a calculation of the cto2 (a-v) value if the po2 value and the so2 is keyed in manually. The calculation is used for evaluating the oxygen consumption of the tissue cells. In the operators manual for abl 700 page 6-24 there is an explanation for this calculation. But the so2 value is not mentioned in the manual, by mistake. In the reference manual the formula is correct. The customer has noticed that the analyzer does not use the same formula for the calculation as mentioned in the manual. If the vlaue for so2 is not keyed in, the analyzer will estimate a value for so2 in relation to the po2 value keyed in. It is not possible to calculate the quantity of the error because of the missing so2 value. But is is possible that a patient migh get maltreated. The formula for this calculation, will be corrected by the next update of the manual.
Patient Sequence No: 1, Text Type: D, B5


MAUDE Entry Details

Report Number3002807968-2006-00022
MDR Report Key699813
Report Source01
Date Received2006-04-10
Date of Report2006-04-10
Date of Event2006-02-24
Date Mfgr Received2006-02-24
Device Manufacturer Date2005-11-01
Date Added to Maude2006-04-17
Event Key0
Report Source CodeManufacturer report
Manufacturer LinkY
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag3
Health Professional3
Initial Report to FDA3
Report to FDA3
Event Location0
Manufacturer ContactLISE-LOTTE RINGBY
Manufacturer StreetAKANDEVEJ 21
Manufacturer CityBRONSHOJ DK-2700
Manufacturer CountryDA
Manufacturer PostalDK-2700
Manufacturer Phone**
Manufacturer G1*
Manufacturer Street*
Manufacturer City*
Manufacturer Country*
Single Use3
Remedial ActionRB
Previous Use Code3
Event Type3
Type of Report3

Device Details

Brand NameABL700SERIES AND ABL800SERIES
Generic NameBLOOD GAZ ANALYZER
Product CodeCCE
Date Received2006-04-10
Model NumberABL825
Catalog Number*
Lot Number*
ID Number*
Device AvailabilityY
Device Eval'ed by MfgrR
Implant FlagN
Date Removed*
Device Sequence No1
Device Event Key688903
ManufacturerRADIOMETER MEDICAL APS
Manufacturer Address* * *
Baseline Brand NameABL700SERIES AND ABL800SERIES
Baseline Generic NameBLOOD GAZ ANALYZER
Baseline Model NoABL825
Baseline Catalog No*
Baseline ID*


Patients

Patient NumberTreatmentOutcomeDate
101. Other 2006-04-10

© 2026 FDA.report