ABL700 AND 800 SERIES/RADIANCE ABL 725 393-725

MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed from a 06 report with the FDA on 2006-04-26 for ABL700 AND 800 SERIES/RADIANCE ABL 725 393-725 manufactured by Radiometer Medical Aps.

Event Text Entries

[447532] A blood gas analysis were made on a abl725 blood gas analyzer. The abl 725 showed a glucose value on approximately 320 mg/dl (17,8 mmol/l). A measurement report printed from a computer with the software radiance, showed a value of approximately 18 'mg/dl' (however, the correct unit and the read out of the abl725 was correct in mmol/l). The interpretation of the report showing the 18 'mg/dl' (wrong unit) was clinically interpreted as very low. This radiance report value of 18 'mg/dl' with an actual correct unit in mmol/l on the abl725 printout was used for the diagnose of the patient, and the patient were treated with medication (probably given glucose i. V. ) to get the glucose to rise. The correct value was 330 mg/dl or the 18,3 mmol/l printout of the abl725. The problem is related to the report printout layout in the radiance system. If the default -r- layout is used, the units will be taken from the database and actual value and units will match. It is, however, possible to hard code the units on the report form, which was done in this case.
Patient Sequence No: 1, Text Type: D, B5


MAUDE Entry Details

Report Number3002807968-2006-00026
MDR Report Key707089
Report Source06
Date Received2006-04-26
Date of Report2006-04-24
Date of Event2006-04-05
Device Manufacturer Date1998-08-01
Date Added to Maude2006-05-04
Event Key0
Report Source CodeManufacturer report
Manufacturer LinkY
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag3
Health Professional3
Initial Report to FDA3
Report to FDA3
Event Location0
Manufacturer ContactLISE-LOTTE RINGBY
Manufacturer StreetAKANDEVEJ 21
Manufacturer CityBRONSHOJ DK-2700
Manufacturer CountryDA
Manufacturer PostalDK-2700
Manufacturer Phone8273827
Manufacturer G1*
Manufacturer Street*
Manufacturer City*
Manufacturer Country*
Single Use3
Previous Use Code3
Event Type3
Type of Report3

Device Details

Brand NameABL700 AND 800 SERIES/RADIANCE
Generic NameBLOOD GAS ANALYZER/RADIANCE
Product CodeCCE
Date Received2006-04-26
Model NumberABL 725
Catalog Number393-725
Lot Number*
ID NumberPRODUCED 08-1998
Device AvailabilityY
Device Eval'ed by MfgrR
Implant FlagN
Date Removed*
Device Sequence No1
Device Event Key696157
ManufacturerRADIOMETER MEDICAL APS
Manufacturer AddressAKANDEVEJ 21 BRONSHOJ DA DK-2700
Baseline Brand NameBLOODGAS ANALYZER
Baseline Generic NameABL 700 SERIES AND ABL 800 SERIES
Baseline Model NoABL 725
Baseline Catalog No*
Baseline ID*


Patients

Patient NumberTreatmentOutcomeDate
101. Death 2006-04-26