MATCH IT! DNA SOFTWARE 888623

MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed with the FDA on 2018-01-19 for MATCH IT! DNA SOFTWARE 888623 manufactured by Immucor Gti Diagnostics, Inc..

Event Text Entries

[98179727] The (b)(6) has reported a complaint ((b)(4)) on (b)(6) 2017 that when using match it! Dna software v1. 2. 3 for hla-a typing, they have observed for 1 sample that the software does not correctly load the suggested assignment table when navigating between samples that contain complex numbers of hla-a allele-string pairs (observed with hla-a*02 homozygous samples). The error occurs when using pairwise off with a win 7 32-bit computer, using 3. 27 allele database. When the user navigates from one sample to the next sample, the software does not automatically assign a typing into the assigned view field when the auto assign feature is activated in preferences. If the user attempts to make a manual assignment to the assigned view field, the software will crash. During the course of the investigation with the customer, the user's software was updated from v1. 2. 3 to v1. 2. 4. An error still occurs in v1. 2. 4, however in this version the when the user navigates from one sample to the next sample, the software maintains the previous sample typing in the assigned view in addition to the suggested assignments. If the user attempts to make a manual assignment, the software will freeze however there is no warning that the typing in assigned view is incorrect.
Patient Sequence No: 1, Text Type: D, B5


MAUDE Entry Details

Report Number2183608-2018-00001
MDR Report Key7207186
Date Received2018-01-19
Date of Report2017-12-21
Date of Event2017-11-15
Date Mfgr Received2017-12-21
Date Added to Maude2018-01-19
Event Key0
Report Source CodeManufacturer report
Manufacturer LinkY
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag3
Health Professional3
Initial Report to FDA3
Report to FDA3
Event Location3
Manufacturer ContactMS. JULIE EWEND
Manufacturer Street20925 CROSSROADS CIRCLE
Manufacturer CityWAUKESHA WI 53186
Manufacturer CountryUS
Manufacturer Postal53186
Manufacturer Phone2627541009
Manufacturer G1IMMUCOR GTI DIAGNOSTICS, INC.
Manufacturer Street20925 CROSSROADS CIRCLE
Manufacturer CityWAUKESHA WI 53186
Manufacturer CountryUS
Manufacturer Postal Code53186
Single Use3
Previous Use Code3
Removal Correction NumberB-0347-0348-2018
Event Type3
Type of Report0

Device Details

Brand NameMATCH IT! DNA SOFTWARE
Generic NameMATCH IT DNA SOFTWARE
Product CodeMZI
Date Received2018-01-19
Catalog Number888623
Device AvailabilityN
Device AgeDA
Device Eval'ed by MfgrY
Device Sequence No1
Device Event Key0
ManufacturerIMMUCOR GTI DIAGNOSTICS, INC.
Manufacturer Address20925 CROSSROADS CIRCLE WAUKESHA 53186 US 53186


Patients

Patient NumberTreatmentOutcomeDate
10 2018-01-19

© 2024 FDA.report
This site is not affiliated with or endorsed by the FDA.