SURESTEP MULTI-DRUG SCREEN TEST UNKNOWN

MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed from a consumer,foreign,health profe report with the FDA on 2018-02-26 for SURESTEP MULTI-DRUG SCREEN TEST UNKNOWN manufactured by Alere San Diego, Inc..

Event Text Entries

[101171017] Investigation conclusion: it is indicated that the product is not returning for evaluation. As the customer did not provide a lot number, a manufacturing record review and testing on reserve sample from the same lot could not be performed. Further investigation is not possible at this time. Based on the information available, there is no indication of a product deficiency. A capa, capa (b)(4), has been opened to address the late documentation of this complaint.
Patient Sequence No: 1, Text Type: N, H10


[101171018] The customer reported receiving negative results for all analytes using a surestep multi-drug screen test with a patient urine sample. All samples at the facility undergo hplc analysis and testing on this sample produced a positive result for benzoylecgonine (cocaine). The customer did not provide a quantitative result but stated the result was above the cut-off value of the screen test. The ph of the urine sample was measured before analysis and resulted in a ph of 14. The customer stated this ph indicated possible modification of the urine. However, there was insufficient sample to repeat the test and the issue could not be replicated by the customer. No additional information provided.
Patient Sequence No: 1, Text Type: D, B5


MAUDE Entry Details

Report Number2027969-2018-00024
MDR Report Key7298160
Report SourceCONSUMER,FOREIGN,HEALTH PROFE
Date Received2018-02-26
Date of Report2018-02-26
Date Mfgr Received2017-04-03
Date Added to Maude2018-02-26
Event Key0
Report Source CodeManufacturer report
Manufacturer LinkY
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag3
Health Professional3
Initial Report to FDA3
Report to FDA3
Event Location3
Manufacturer ContactYA-LING KING
Manufacturer Street9975 SUMMERS RIDGE ROAD
Manufacturer CitySAN DIEGO CA 92121
Manufacturer CountryUS
Manufacturer Postal92121
Manufacturer Phone8588052084
Single Use3
Previous Use Code3
Event Type3
Type of Report3

Device Details

Brand NameSURESTEP MULTI-DRUG SCREEN TEST
Generic NameENZYME IMMUNOASSAY, COCAINE AND COCAINE METABOLITES
Product CodeDIO
Date Received2018-02-26
Model NumberUNKNOWN
Lot NumberUNKNOWN
OperatorHEALTH PROFESSIONAL
Device AvailabilityN
Device Eval'ed by MfgrR
Device Sequence No1
Device Event Key0
ManufacturerALERE SAN DIEGO, INC.
Manufacturer Address9975 SUMMERS RIDGE ROAD SAN DIEGO CA 92121 US 92121


Patients

Patient NumberTreatmentOutcomeDate
10 2018-02-26

© 2026 FDA.report
This site is not affiliated with or endorsed by the FDA.