LIFECODES HLA-B SSO TYPING KIT, LIFECODES HLA-B ERES SSO TYPING KIT 628915

MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed from a foreign,health professional,u report with the FDA on 2018-05-24 for LIFECODES HLA-B SSO TYPING KIT, LIFECODES HLA-B ERES SSO TYPING KIT 628915 manufactured by Immucor Gti Diagnostics, Inc..

Event Text Entries

[109635202] Customer complaint was received on march 2, 2018 ((b)(4)) describing that when reports were generated using product number 628915, lot number 01117a of lifecodes hla-b sso typing kit the serological equivalent for b*27:08 was shown to be bw4 rather than the correct bw6. Immucor gti diagnostics quality control reviewed the complaint and discovered that the change was due to a transcription error during creation of hla-b probe hit tables for 3. 29. 0 allele database serological equivalence file of the database files. The hla-b allele b*27:08 serological equivalence changed from a b27 (bw6) in allele database 3. 27. 0 to b2708 (bw4) in allele database 3. 29. 0. The hla-b allele b*27:08 serological equivalence was incorrectly assigned bw4. An ncr (ncr 1762) was opened to address the issue. Resolution of this error was made with a correction to the database, a customer notification (correction) and a technical update loaded to the immucor website for the affected lots of product. The serological equivalent (bw4 or bw6) is assigned by the world health organization (who). Lifecodes hla sso-b typing kit or lifecodes hla sso-beres affected kits: product name: lifecodes hla-b sso typing kit, lot#/serial #: 01117a, list # part#: 628915, expiration date: 2018-11-30; lifecodes hla-b sso typing kit, 06036a, 628915, 2018-05-31; lifecodes hla-beres sso typing kit, 01117b, 628917, 2018-12-31; lifecodes hla-beres sso typing kit, 06036b, 628917, 2018-12-31. The lifecodes hla sso-b and hla sso-b eres typing kits are meeting performance claims. This issue is a documentation error not associated with a performance claim or who standard.
Patient Sequence No: 1, Text Type: D, B5


MAUDE Entry Details

Report Number2183608-2018-00011
MDR Report Key7542142
Report SourceFOREIGN,HEALTH PROFESSIONAL,U
Date Received2018-05-24
Date of Report2018-03-02
Date of Event2018-02-26
Date Mfgr Received2018-03-02
Device Manufacturer Date2017-03-16
Date Added to Maude2018-05-24
Event Key0
Report Source CodeManufacturer report
Manufacturer LinkY
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag3
Health Professional3
Initial Report to FDA3
Report to FDA3
Event Location3
Manufacturer ContactMS JULIE EWEND
Manufacturer Street20925 CROSSROADS CIRCLE
Manufacturer CityWAUKESHA WI 53186
Manufacturer CountryUS
Manufacturer Postal53186
Manufacturer Phone2627541009
Manufacturer G1IMMUCOR GTI DIAGNOSTICS, INC.
Manufacturer Street20925 CROSSROADS CIRCLE
Manufacturer CityWAUKESHA WI 53186
Manufacturer CountryUS
Manufacturer Postal Code53186
Single Use3
Remedial ActionRC
Previous Use Code3
Event Type3
Type of Report3

Device Details

Brand NameLIFECODES HLA-B SSO TYPING KIT, LIFECODES HLA-B ERES SSO TYPING KIT
Generic NameQUALITATIVE TEST FOR HLA, NON-DIAGNOSTIC
Product CodeMZI
Date Received2018-05-24
Catalog Number628915
Lot Number01117A
Device Expiration Date2018-11-30
OperatorMEDICAL TECHNOLOGIST
Device AvailabilityN
Device Eval'ed by MfgrR
Device Sequence No1
Device Event Key0
ManufacturerIMMUCOR GTI DIAGNOSTICS, INC.
Manufacturer Address20925 CROSSROADS CIRCLE WAUKESHA WI 53186 US 53186


Patients

Patient NumberTreatmentOutcomeDate
10 2018-05-24

© 2026 FDA.report