LIFECODES HLA-DQA1/B1 SSO TYPING KIT 628930

MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed from a user facility report with the FDA on 2018-07-20 for LIFECODES HLA-DQA1/B1 SSO TYPING KIT 628930 manufactured by Immucor Gti Diagnostics, Inc..

Event Text Entries

[114814281] Customer contacted immucor on (b)(6) 2018 ((b)(4)) regarding a sample in which an allele dropout was suspected with lifecodes hla-dqa1/b1 sso typing kit lot 3004970. The sample was tested and originally resulted in a dqb1 typing of dq5 homozygous with an exact match by the software. The customer suspected a possible allele dropout with the sample and retested the sample with sequence-specific primer (ssp). This resulted in a dqb1 heterozygous typing of dq5/dq9. The sample was then retested by lifecodes sso, resulting in a review probes prompt by the software. The sample required two manual bead changes to result in the heterozygous typing dq5/dq9. The customer stated that they follow immucor product storage and ifu protocols. The incorrect typing was not reported out by the customer. The sample was repeated and the correct results reported out. The customer decided to repeat the sample testing by both ssp and sso due to known gene linkages and also because what the customer considers false negative dq3 probes, were within 30% range from threshold for the sample. The customer will continue to monitor this issue.
Patient Sequence No: 1, Text Type: D, B5


MAUDE Entry Details

Report Number2183608-2018-00004
MDR Report Key7707535
Report SourceUSER FACILITY
Date Received2018-07-20
Date of Report2018-01-12
Date of Event2018-01-09
Date Mfgr Received2018-01-12
Device Manufacturer Date2017-04-20
Date Added to Maude2018-07-20
Event Key0
Report Source CodeManufacturer report
Manufacturer LinkY
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag3
Health Professional3
Initial Report to FDA3
Report to FDA3
Event Location3
Manufacturer ContactERIKA HEWITT
Manufacturer Street20925 CROSSROADS CIRCLE
Manufacturer CityWAUKESHA WI 53186
Manufacturer CountryUS
Manufacturer Postal53186
Manufacturer Phone2627541006
Manufacturer G1IMMUCOR GTI DIAGNOSTICS, INC.
Manufacturer Street20925 CROSSROADS CIRCLE
Manufacturer CityWAUKESHA WI 53186
Manufacturer CountryUS
Manufacturer Postal Code53186
Single Use3
Previous Use Code3
Event Type3
Type of Report3

Device Details

Brand NameLIFECODES HLA-DQA1/B1 SSO TYPING KIT
Generic NameLIFECODES HLA-DQA1/B1 SSO TYPING KIT
Product CodeMZI
Date Received2018-07-20
Catalog Number628930
Lot Number3004970
Device Expiration Date2018-06-15
Device AvailabilityN
Device Eval'ed by MfgrN
Device Sequence No1
Device Event Key0
ManufacturerIMMUCOR GTI DIAGNOSTICS, INC.
Manufacturer Address20925 CROSSROADS CIRCLE WAUKESHA WI 53186 US 53186


Patients

Patient NumberTreatmentOutcomeDate
10 2018-07-20

© 2024 FDA.report
This site is not affiliated with or endorsed by the FDA.