NRG TRANSSEPTAL NEEDLE NRG-E-HF-71-C0

MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed from a distributor report with the FDA on 2018-07-26 for NRG TRANSSEPTAL NEEDLE NRG-E-HF-71-C0 manufactured by Baylis Medical Company Inc..

Event Text Entries

[115188826] The reported patient complication is an inherent risk to this type of procedure.
Patient Sequence No: 1, Text Type: N, H10


[115188827] A report was received indicating that tamponade occurred in patient during an ablation procedure in which the baylis medical nrg transseptal needle (rf needle) was used for transseptal puncture. Successful transseptal puncture was achieved with the rf needle using the baylis rf generator (pulse setting of 1 second). However, the rf needle inadvertently perforated the posterior wall. The distal tip of the rf needle was confirmed to be protruding from the cardiac silhouette by fluoroscopy. The rf needle was removed from the patient and pericardiocentesis was performed. Following confirmation that the patient was in stable condition, the ablation procedure continued and was completed without further complications.
Patient Sequence No: 1, Text Type: D, B5


MAUDE Entry Details

Report Number9710452-2018-00029
MDR Report Key7724553
Report SourceDISTRIBUTOR
Date Received2018-07-26
Date of Report2018-07-26
Date of Event2016-04-05
Date Mfgr Received2018-06-28
Date Added to Maude2018-07-26
Event Key0
Report Source CodeManufacturer report
Manufacturer LinkY
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag3
Health Professional3
Initial Report to FDA3
Report to FDA3
Event Location3
Manufacturer ContactDR. MEGHAL KHAKHAR
Manufacturer Street2775 MATHESON BLVD. EEAST
Manufacturer CityMISSISSAUGA, ONTARIO L4W 4P7
Manufacturer CountryCA
Manufacturer PostalL4W 4P7
Manufacturer G1BAYLIS MEDICAL COMPANY INC.
Manufacturer Street2775 MATHESON BLVD. EAST
Manufacturer CityMISSISSAUGA, ONTARIO L4W 4P7
Manufacturer CountryCA
Manufacturer Postal CodeL4W 4P7
Single Use3
Previous Use Code3
Event Type3
Type of Report3

Device Details

Brand NameNRG TRANSSEPTAL NEEDLE
Generic NameRF TRANSSEPTAL NEEDLE
Product CodeDXF
Date Received2018-07-26
Model NumberNRG-E-HF-71-C0
Catalog NumberNRG-E-HF-71-C0
Device AvailabilityN
Device Eval'ed by MfgrN
Device Sequence No1
Device Event Key0
ManufacturerBAYLIS MEDICAL COMPANY INC.
Manufacturer Address5959 TRANS-CANADA HIGHWAY MONTREAL, QUEBEC H4T 1A1 CA H4T 1A1


Patients

Patient NumberTreatmentOutcomeDate
101. Required No Informationntervention 2018-07-26

© 2026 FDA.report
This site is not affiliated with or endorsed by the FDA.