[120969437] No product is being returned for evaluation but lot # is provided. A device history report is to be reviewed by engineering. A final report will be sent once the results have been analyzed.
Patient Sequence No: 1, Text Type: N, H10


[120969438] Procedure performed: partial knee arthroplasty. On (b)(6) 2018, c8322 xs alexis wound protector/retractor, lot# 1322872, was used by surgeon at medical center for a partial knee arthroplasty. He knew that the model was not the orthopaedic version but used it anyway. During the procedure, the alexis protector sheath was torn by instrumentation. The staff retrieved the sheath before continuing with the procedure. Surgeon recap of incident: drilled one of the pins through the polyurethane and it wound itself around the pin. Surgeon error! I should have retracted more carefully. All the pieces were wrapped around the pin not loose in the knee. Type of intervention: unknown. Patient status: no patient injury.
Patient Sequence No: 1, Text Type: D, B5


MAUDE Entry Details

Report Number2027111-2018-00359
MDR Report Key7895055
Report SourceCOMPANY REPRESENTATIVE,HEALTH
Date Received2018-09-20
Date of Report2019-01-14
Date of Event2018-08-20
Date Mfgr Received2018-08-21
Device Manufacturer Date2018-04-17
Date Added to Maude2018-09-20
Event Key0
Report Source CodeManufacturer report
Manufacturer LinkY
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag3
Health Professional3
Initial Report to FDA3
Report to FDA3
Event Location3
Manufacturer ContactWENDY KOBAYASHI
Manufacturer Street22872 AVENIDA EMPRESA
Manufacturer CityRANCHO SANTA MARGARITA CA 92688
Manufacturer CountryUS
Manufacturer Postal92688
Manufacturer Phone9497138059
Manufacturer G1APPLIED MEDICAL RESOURCES
Manufacturer Street22872 AVENIDA EMPRESSA
Manufacturer CityRANCHO SANTA MARGARITA CA 92688
Manufacturer CountryUS
Manufacturer Postal Code92688
Single Use3
Previous Use Code3
Removal Correction NumberNA
Event Type3
Type of Report3

Device Details

Brand NameC8322, XS ALEXIS WND PROT/RET SHRT 5/BX
Generic NameKGW
Product CodeKGW
Date Received2018-09-20
Model NumberC8322
Catalog Number101432501
Lot Number1322872
OperatorHEALTH PROFESSIONAL
Device AvailabilityN
Device AgeDA
Device Eval'ed by MfgrR
Device Sequence No1
Device Event Key0
ManufacturerAPPLIED MEDICAL RESOURCES
Manufacturer Address22872 AVENIDA EMPRESSA RANCHO SANTA MARGARITA CA 92688 US 92688


Patients

Patient NumberTreatmentOutcomeDate
10 2018-09-20