NAVIGATOR HD M0062502250 70388

MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed from a company representative,health report with the FDA on 2018-09-25 for NAVIGATOR HD M0062502250 70388 manufactured by Boston Scientific Corporation.

Event Text Entries

[121619813] The complainant was unable to provide the lot number. Therefore, the manufacture and expiration dates are unknown. According to the complainant, the suspect device has been disposed and is not available for return. If any further relevant information is received, a supplemental mdr will be filed.
Patient Sequence No: 1, Text Type: N, H10


[121619814] It was reported to boston scientific corporation that a navigator hd ureteral access sheath was used in the ureter during an ureteroscopy procedure performed on (b)(6) 2018. According to the complainant, during the procedure, a perforation occurred while the physician was advancing the access sheath over the sensor wire. A percutaneous tube was placed to drain the kidney. The procedure was not completed due to this event. In the physicians assessment, the physician felt that the navigator was too stiff. The patient's condition at the conclusion of the procedure was reported to be doing well.
Patient Sequence No: 1, Text Type: D, B5


MAUDE Entry Details

Report Number3005099803-2018-60548
MDR Report Key7906575
Report SourceCOMPANY REPRESENTATIVE,HEALTH
Date Received2018-09-25
Date of Report2018-09-25
Date of Event2018-09-05
Date Mfgr Received2018-09-05
Date Added to Maude2018-09-25
Event Key0
Report Source CodeManufacturer report
Manufacturer LinkY
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag3
Health Professional3
Initial Report to FDA3
Report to FDA3
Event Location3
Manufacturer ContactCAROLE MORLEY
Manufacturer Street300 BOSTON SCIENTIFIC WAY
Manufacturer CityMARLBOROUGH MA 01752
Manufacturer CountryUS
Manufacturer Postal01752
Manufacturer Phone5086834015
Manufacturer G1BOSTON SCIENTIFIC CORPORATION
Manufacturer Street780 BROOKSIDE DRIVE
Manufacturer CitySPENCER IN 47460
Manufacturer CountryUS
Manufacturer Postal Code47460
Single Use3
Previous Use Code3
Event Type3
Type of Report3

Device Details

Brand NameNAVIGATOR HD
Generic NameENDOSCOPIC ACCESS OVERTUBE, GASTROENTEROLOGY-UROLOGY
Product CodeFED
Date Received2018-09-25
Model NumberM0062502250
Catalog Number70388
OperatorHEALTH PROFESSIONAL
Device AvailabilityN
Device Eval'ed by MfgrR
Device Sequence No1
Device Event Key0
ManufacturerBOSTON SCIENTIFIC CORPORATION
Manufacturer Address300 BOSTON SCIENTIFIC WAY MARLBOROUGH MA 01752 US 01752


Patients

Patient NumberTreatmentOutcomeDate
101. Required No Informationntervention 2018-09-25