GAS SUPPLY MODULE 900IW104

MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed with the FDA on 2018-10-11 for GAS SUPPLY MODULE 900IW104 manufactured by Fisher & Paykel Healthcare Ltd.

Event Text Entries

[123956991] (b)(4). The 900iw104 gas supply module is an accessory that can be supplied with the iw932 cosycot infant warmer. The 900iw104 gas supply module is not sold in the usa, but it is similar to the 900iw101 gas supply module, which is sold in the usa. Sms technologies (uk) is the manufacturer of the oxygen/air gas supply module (sms technologies part number fp900iw104s). Sms technologies has ceased trading, thus they could not be notified of this complaint. Method: the complaint 900iw104 gas supply module was not returned to fisher & paykel healthcare in (b)(4) for investigation. Our investigation is thus based on the information provided by the customer. Results: the customer informed us that the air regulator on the subject gas supply module was leaking air when turned on. The customer stated that the air regulator on the subject gas supply module was replaced with a new air regulator and the issue was resolved. Conclusion: we are unable to determine what caused the leak in the gas supply module as reported by the customer, however based on the information provided, it was likely caused by a faulty air regulator.
Patient Sequence No: 1, Text Type: N, H10


[123956992] A hospital in (b)(6) reported via a fisher & paykel healthcare representative that clinical staff needed to use the resuscitation module on the iw932 cosycot infant warmer during an emergency, however gas was found leaking from the 900iw104 gas supply module and therefore it was unable to be used. There was no patient involvement.
Patient Sequence No: 1, Text Type: D, B5


MAUDE Entry Details

Report Number9611451-2018-00856
MDR Report Key7958979
Date Received2018-10-11
Date of Report2018-09-14
Date Mfgr Received2018-09-14
Date Added to Maude2018-10-11
Event Key0
Report Source CodeManufacturer report
Manufacturer LinkY
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag3
Reporter OccupationOTHER HEALTH CARE PROFESSIONAL
Health Professional3
Initial Report to FDA3
Report to FDA3
Event Location3
Manufacturer ContactMS FARANAK GOMAROONI
Manufacturer Street173 TECHNOLOGY DRIVE SUITE 100
Manufacturer CityIRVINE CA 92618
Manufacturer CountryUS
Manufacturer Postal92618
Manufacturer Phone9494534000
Manufacturer G1FISHER & PAYKEL HEALTHCARE LTD
Manufacturer Street15 MAURICE PAYKEL PLACE EAST TAMAKI
Manufacturer CityAUCKLAND, 2013
Manufacturer CountryNZ
Manufacturer Postal Code2013
Single Use3
Previous Use Code3
Event Type3
Type of Report0

Device Details

Brand NameGAS SUPPLY MODULE
Generic NameBYX
Product CodeBYX
Date Received2018-10-11
Returned To Mfg2018-11-06
Model Number900IW104
Catalog Number900IW104
Lot NumberNOT PROVIDED
OperatorHEALTH PROFESSIONAL
Device AvailabilityR
Device AgeDA
Device Eval'ed by MfgrY
Device Sequence No1
Device Event Key0
ManufacturerFISHER & PAYKEL HEALTHCARE LTD
Manufacturer Address15 MAURICE PAYKEL PLACE EAST TAMAKI AUCKLAND, 2013 NZ 2013


Patients

Patient NumberTreatmentOutcomeDate
10 2018-10-11

© 2026 FDA.report
This site is not affiliated with or endorsed by the FDA.