DADE ACTIN FSL ACTIVATED PTT REAGENT 10445714

MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed from a health professional,user faci report with the FDA on 2018-10-12 for DADE ACTIN FSL ACTIVATED PTT REAGENT 10445714 manufactured by Siemens Healthcare Diagnostics Product Gmbh.

Event Text Entries

[126072720] A customer contacted a siemens customer care center (ccc) and indicated that they obtained a discordant activated partial thromboplastin time (aptt) result on a patient sample using the dade actin fsl activated ptt reagent. As per siemens' instructions, the customer performed a precision study using quality controls, resulting acceptably. Siemens investigated the instrument files and observed that the samples were flagged with err 128 (early reaction error) and err 004 (analysis time over) and discordant results were only obtained for this patient. The sysmex ca-1500 system advises customers that an abnormal reaction was detected at the initial stage of the coagulation because of a reagent problem and to check the coagulation curve, increase the maximum detection time and check the status of the sample and reagent for re-analysis when these errors are triggered during sample analysis. Quality controls (qcs) recovered within lab ranges on the day of the event. The customer suspected that the samples were contaminated. Siemens further investigated the event and determined that there were no mechanical or analysis errors, indicating there were no system malfunctions. Siemens concluded that the cause of the discordant, falsely low aptt result was sample specific and was potentially caused by pre-analytical factors. The system and reagent are performing according to specifications. No further evaluation of these devices is required. Mdr 9610806-2018-00105 was filed for the same issue.
Patient Sequence No: 1, Text Type: N, H10


[126072721] A low activated partial thromboplastin time (aptt) result of 30 seconds was obtained on one patient sample using the dade actin fsl activated ptt reagent on a sysmex ca-1500 system. The initial result was reported to the physician(s). The following day, one of the samples from the patient and a new redrawn sample were rerun on the same system and on an alternate sysmex ca-1500 system using the same reagents, from the same lot, resulting higher. One of the repeat results was reported, as the correct results, to the physician(s). There are no known reports of patient intervention or adverse health consequences due to the previously obtained aptt results.
Patient Sequence No: 1, Text Type: D, B5


MAUDE Entry Details

Report Number9610806-2018-00104
MDR Report Key7962398
Report SourceHEALTH PROFESSIONAL,USER FACI
Date Received2018-10-12
Date of Report2018-10-12
Date of Event2018-09-18
Date Mfgr Received2018-09-19
Device Manufacturer Date2017-10-11
Date Added to Maude2018-10-12
Event Key0
Report Source CodeManufacturer report
Manufacturer LinkY
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag3
Reporter OccupationOTHER HEALTH CARE PROFESSIONAL
Health Professional3
Initial Report to FDA3
Report to FDA3
Event Location3
Manufacturer ContactCHRISTINA LAM
Manufacturer Street511 BENEDICT AVE
Manufacturer CityTARRYTOWN NY 10591
Manufacturer CountryUS
Manufacturer Postal10591
Manufacturer Phone9145243504
Manufacturer G1SIEMENS HEALTHCARE DIAGNOSTICS PRODUCT GMBH
Manufacturer StreetEMIL-VON-BEHRING-STR 76
Manufacturer CityMARBURG, D-35041
Manufacturer CountryGM
Manufacturer Postal CodeD-35041
Single Use3
Previous Use Code3
Event Type3
Type of Report3

Device Details

Brand NameDADE ACTIN FSL ACTIVATED PTT REAGENT
Generic NameDADE ACTIN FSL ACTIVATED PTT REAGENT
Product CodeGGW
Date Received2018-10-12
Model NumberDADE ACTIN FSL ACTIVATED PTT REAGENT
Catalog Number10445714
Lot Number556922A
Device Expiration Date2019-10-04
OperatorHEALTH PROFESSIONAL
Device AvailabilityN
Device Eval'ed by MfgrN
Device Sequence No1
Device Event Key0
ManufacturerSIEMENS HEALTHCARE DIAGNOSTICS PRODUCT GMBH
Manufacturer AddressEMIL-VON-BEHRING-STR 76 MARBURG, D-35041 GM D-35041


Patients

Patient NumberTreatmentOutcomeDate
10 2018-10-12

© 2026 FDA.report
This site is not affiliated with or endorsed by the FDA.