CRYOMACS FREEZING BAG 500

MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed with the FDA on 2018-11-06 for CRYOMACS FREEZING BAG 500 manufactured by Miltenyi Biotec Gmbh.

Event Text Entries

[126973115] Bmt lab technologist performed cell processing procedure for an autologous hpc, apheresis cellular therapy product (ctp) with unique id (b)(4) on (b)(6) 2018 in preparation for cryopreservation and long term ln2 vapor phase storage of the product. The technologist dispensed all components of the cryopreservation solution into the cryo bag without incident. During the final step of the processing procedure when dispensing the ctp aliquot into the cro bag containing the cryopreservation solution, the technologist observed a small amount of leakage of the cryo bag contents. Visual observation of the croy bag to locate the source of the leak revealed an integrity failure of a very small nick in the cryo bag material located at the base of the bag just above the bottom seam weld. The bmt lab technologist immediately initiated cell product rescue measures clamping off the affected area of the cryo bag to prevent add'l leakage of the product and worked quickly to transfer the product to a new intact cryo bag. The product was subsequently cryopreserved and stored in ln2 vapor phase storage without incident. The cell loss resulting from the leakage was determined to be minimal, however the product was sampled for sterility after transfer of the product to the secondary bag. Sterility testing was resulted as "no growth 14 days. "
Patient Sequence No: 1, Text Type: D, B5


MAUDE Entry Details

Report NumberMW5081124
MDR Report Key8046239
Date Received2018-11-06
Date of Report2018-11-02
Date of Event2018-08-22
Date Added to Maude2018-11-07
Event Key0
Report Source CodeVoluntary report
Manufacturer LinkN
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag3
Reporter OccupationOTHER HEALTH CARE PROFESSIONAL
Health Professional3
Initial Report to FDA3
Report to FDA3
Event Location3
Single Use3
Previous Use Code3
Event Type3
Type of Report0

Device Details

Brand NameCRYOMACS FREEZING BAG 500
Generic NameCONTAINER, EMPTY, FOR COLLECTION AND PROCESSING OF BLOOD AND BLOOD COMPONENTS
Product CodeKSR
Date Received2018-11-06
Model NumberCRYOMACS FREEZING BAG 500
Lot Number6170615001
OperatorHEALTH PROFESSIONAL
Device AvailabilityY
Device Eval'ed by Mfgr*
Device Sequence No1
Device Event Key0
ManufacturerMILTENYI BIOTEC GMBH
Manufacturer AddressBERGISCH GLADBACH NORTH-RHINE-WESTPHALIA 51429 GM 51429


Patients

Patient NumberTreatmentOutcomeDate
101. Other 2018-11-06