VITROS CHEMISTRY PRODUCTS CA SLIDES 1450261

MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed with the FDA on 2018-12-06 for VITROS CHEMISTRY PRODUCTS CA SLIDES 1450261 manufactured by Ortho-clinical Diagnostics.

Event Text Entries

[130622097] The investigation determined that lower than expected vitros calcium (ca) quality control (qc) results were attained using vitros chemistry products ca slides and vitros chemistry products performance verifiers in combination with a vitros 350 chemistry system. A definitive assignable cause could not be determined. However, based on the information available, a potential cause of this event is a non-reactive cartridge where the integrity of the foil wrapper is compromised during shipment or storage on site, exposing the slides to ambient conditions. However, this could not be verified. The lower than expected vitros ca results were isolated to two slide cartridges from the same box of vitros ca slides. Acceptable vitros ca results were obtained from the cartridges in use prior to the affected cartridges and using an alternate slide cartridge (same lot) after the affected slide cartridges were unloaded from the instrument. A review of historical vitros ca quality control data indicated acceptable qc performance apart from results obtained from the two suspect vitros ca cartridges. Ongoing tracking and trending of complaints has not identified any signals that would suggest there is a systemic issue with vitros ca slide lot 0313-0571-9275. Within-run precision testing used to assess the performance of the vitros 350 chemistry system was performed and acceptable results were attained. Therefore, an instrument issue was ruled out as a contributor to this event.
Patient Sequence No: 1, Text Type: N, H10


[130622098] A customer reported lower than expected vitros calcium (ca) quality control (qc) results obtained using vitros chemistry products ca slides and vitros chemistry products performance verifiers in combination with a vitros 350 chemistry system. Vitros performance verifier ii lot x5905 results of 8. 66, 8. 49 and 8. 56 mg/dl versus the expected result of 12. 1 mg/dl biased results of the magnitude and direction observed may lead to inappropriate physician action if they were to occur undetected on patient samples. There was no allegation of patient harm as a result of this event. This report is number 3 of 3 mdr? S for this event. Three (3) 3500a forms are being submitted for this event as 3 devices were involved. This report corresponds to ortho clinical diagnostics inc. Complaint number (b)(4).
Patient Sequence No: 1, Text Type: D, B5


MAUDE Entry Details

Report Number1319809-2018-00150
MDR Report Key8139237
Date Received2018-12-06
Date of Report2018-12-06
Date of Event2018-11-08
Date Mfgr Received2018-11-08
Device Manufacturer Date2018-05-11
Date Added to Maude2018-12-06
Event Key0
Report Source CodeManufacturer report
Manufacturer LinkY
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag3
Health Professional3
Initial Report to FDA3
Report to FDA3
Event Location3
Manufacturer ContactMR. JAMES A STEVENS
Manufacturer Street100 INDIGO CREEK DRIVE
Manufacturer CityROCHESTER NY 14626
Manufacturer CountryUS
Manufacturer Postal14626
Manufacturer Phone5854533000
Manufacturer G1ORTHO-CLINICAL DIAGNOSTICS
Manufacturer Street513 TECHNOLOGY BLVD.
Manufacturer CityROCHESTER NY 14652
Manufacturer CountryUS
Manufacturer Postal Code14652
Single Use3
Previous Use Code3
Event Type3
Type of Report0

Device Details

Brand NameVITROS CHEMISTRY PRODUCTS CA SLIDES
Generic NameIN VITRO DIAGNOSTICS
Product CodeCJY
Date Received2018-12-06
Catalog Number1450261
Lot Number0313-0571-9275
Device Expiration Date2019-10-01
OperatorHEALTH PROFESSIONAL
Device AvailabilityY
Device Eval'ed by MfgrY
Device Sequence No1
Device Event Key0
ManufacturerORTHO-CLINICAL DIAGNOSTICS
Manufacturer Address100 INDIGO CREEK DRIVE ROCHESTER NY 14626 US 14626


Patients

Patient NumberTreatmentOutcomeDate
10 2018-12-06

© 2026 FDA.report
This site is not affiliated with or endorsed by the FDA.