MCB 212 DUAL TANK MIX & DELIVERY BICARB SYSTEM

MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed from a company representative,user f report with the FDA on 2018-12-07 for MCB 212 DUAL TANK MIX & DELIVERY BICARB SYSTEM manufactured by Mar Cor Purification.

Event Text Entries

[129751916] The facility reported the incorrect concentration of bicarbonate solution from the mcb 212 bicarb system was delivered from the distribution tank to the loop and to patients. The concentration of bicarbonate solution was diluted due to an operator leaving a valve open while cleaning the mix tank during patient treatments. (twelve (12) patients were receiving dialysis treatment at the time. The facility reported patients were experiencing cramping. According to the facility, the bicarbonate solution in the distribution tank was accidentally diluted as an operator left a valve open while they were cleaning the mix tank during patient treatments. Ro water from the mix tank combined with the outgoing bicarb solution from the distribution tank causing more unused fluid from the loop to be returned to the distribution tank, thus further diluting the bicarb solution. This resulted in the dialysis machines alarming for low level. Video footage from the facility confirmed the solution level increase in the distribution tank and they observed one of the staff members cleaning the mix tank and not properly shut off the valves. The mcb 212 bicarb system user manual clearly warns users not to disinfect the mix tank while dialyzing patients as possible harm could occur. The facility reported to have retrained their staff to prevent this issue from reoccurring. Mar cor purification regulatory followed up with the facility and they reported a nurse followed up with all the patients receiving dialysis at the time and confirmed they were all doing better. No additional medical attention was sought. This complaint will continue being monitored in mar cor purification's complaint handling system.
Patient Sequence No: 1, Text Type: N, H10


[129751917] The facility reported the incorrect concentration of bicarbonate solution from the mcb 212 bicarb system was delivered from the distribution tank to the loop and to patients. The concentration of bicarbonate solution was diluted due to an operator leaving a valve open while cleaning the mix tank during patient treatments. Twelve (12) patients were receiving dialysis treatment at the time. The facility reported patients were experiencing cramping.
Patient Sequence No: 1, Text Type: D, B5


MAUDE Entry Details

Report Number3019131-2018-00003
MDR Report Key8144049
Report SourceCOMPANY REPRESENTATIVE,USER F
Date Received2018-12-07
Date of Report2018-12-07
Date of Event2018-11-14
Date Mfgr Received2018-11-14
Date Added to Maude2018-12-07
Event Key0
Report Source CodeManufacturer report
Manufacturer LinkY
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag3
Health Professional3
Initial Report to FDA3
Report to FDA3
Event Location3
Manufacturer ContactALEX NELSON
Manufacturer Street14550 28TH AVE N.
Manufacturer CityPLYMOUTH MN 55447
Manufacturer CountryUS
Manufacturer Postal55447
Manufacturer Phone7635094799
Manufacturer G1MAR COR PURIFICATION
Manufacturer Street14550 28TH AVE N.
Manufacturer CityPLYMOUTH MN 55447
Manufacturer CountryUS
Manufacturer Postal Code55447
Single Use3
Previous Use Code3
Event Type3
Type of Report3

Device Details

Brand NameMCB 212 DUAL TANK MIX & DELIVERY BICARB SYSTEM
Generic NameBICARB SYSTEM
Product CodeFIN
Date Received2018-12-07
Model NumberMCB 212
Device AvailabilityY
Device Eval'ed by MfgrR
Device Sequence No1
Device Event Key0
ManufacturerMAR COR PURIFICATION
Manufacturer Address14550 28TH AVE N. PLYMOUTH MN 55447 US 55447


Patients

Patient NumberTreatmentOutcomeDate
101. Other 2018-12-07

© 2026 FDA.report
This site is not affiliated with or endorsed by the FDA.