MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed with the FDA on 2018-12-11 for TRUCLIP TCLIP05 manufactured by Edwards Lifesciences Dr.

Event Text Entries

[130659460] The device was not returned for evaluation; it was discarded at the hospital. Without return of the unit it is not possible to determine if some damage or defect existed on the unit that could have contributed to the event. It is not known if some procedural factors may have contributed to the event. No corrective actions will be taken at this time. Lot number was not provided; therefore review of the manufacturing records could not be completed. The truclip is designed to keep the pressure transducer at the phlebostatic axis for accurate pressure readings. In the event that the truclip is broken and does not remain stationary on the iv pole, it is possible to receive inaccurate pressure values. Pressure readings should correlate with the patient? S clinical manifestations. The truclip ifu includes a warning that states:? Truclip must be mounted securely to ensure clinical stability and to prevent injury to the patient or user?. The ifu also advises the clinician to clean the surface of the truclip before and after each use by wiping with 70% isopropyl alcohol or 5% bleach and inspect to ensure the integrity of the device. There is a caution in the ifu instructing the user not to sterilize the truclip. It is common clinical practice for the clinician to monitor the transducer vent port so that it corresponds to the chamber where the pressure is being measured. Clinicians routinely follow hospital policies and procedures for frequency of zeroing the transducer system and thereby monitoring the level of the truclip device. In this case the facility did not follow edwards instructions to not sterilize. Complaint histories for all reported events are reviewed against trending control limits on a monthly basis, and any excursions above the control limits are assessed and documented as part of this monthly review. This is a 510k exempt as this is a class 1 device. Medwatch report number mw5081036.
Patient Sequence No: 1, Text Type: N, H10


[130659462] It was reported while measuring the patient? S blood pressure, unknown to the nurse, the arterial blood pressure transducer had fallen off the clip and the blood pressure readings were falsely elevated and the medication was decreased based on the incorrect readings. After the event, inspection of the equipment found that the holders were warping due to the sterilization process. (sterilization is not recommended by manufacturer. ) patient demographics unable to be obtained. Follow up attempts have been made for the patient? S condition. The device was discarded at the hospital.
Patient Sequence No: 1, Text Type: D, B5


MAUDE Entry Details

Report Number2015691-2018-05206
MDR Report Key8151775
Date Received2018-12-11
Date of Report2018-11-19
Date of Event2018-05-14
Date Mfgr Received2018-11-19
Date Added to Maude2018-12-11
Event Key0
Report Source CodeManufacturer report
Manufacturer LinkY
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag3
Reporter OccupationOTHER HEALTH CARE PROFESSIONAL
Health Professional3
Initial Report to FDA3
Report to FDA3
Event Location3
Manufacturer ContactMRS LYNN SELAWSKI
Manufacturer Street1 EDWARDS WAY
Manufacturer CityIRVINE CA 92614
Manufacturer CountryUS
Manufacturer Postal92614
Manufacturer Phone9497564386
Manufacturer G1EDWARDS LIFESCIENCES DR
Manufacturer StreetPARQUE INDUSTRIAL DE ITABO CARR. SANCHEZ KM 18.5
Manufacturer CityHAINA, SAN CRISTOBAL
Manufacturer CountryDR
Single Use3
Previous Use Code3
Event Type3
Type of Report0

Device Details

Brand NameTRUCLIP
Generic NameSTAND, INFUSION
Product CodeFOX
Date Received2018-12-11
Model NumberTCLIP05
OperatorHEALTH PROFESSIONAL
Device AvailabilityN
Device Eval'ed by MfgrN
Device Sequence No1
Device Event Key0
ManufacturerEDWARDS LIFESCIENCES DR
Manufacturer AddressPARQUE INDUSTRIAL DE ITABO CARR. SANCHEZ KM 18.5 HAINA, SAN CRISTOBAL DR


Patients

Patient NumberTreatmentOutcomeDate
101. Other 2018-12-11

© 2024 FDA.report
This site is not affiliated with or endorsed by the FDA.