N
Patient 1
INVESTIGATION: NO PRODUCT WAS RETURNED. THEREFORE, A PRODUCT INVESTIGATION COULD NOT BE PERFORMED. A THEORETICAL ASSESSMENT IS MADE BASED ON THE GIVEN COMPLAINT DESCRIPTION, PRODUCT-IFUS AND INTERNAL DOCUMENTS. THE COMPLAINT REPORT AND THE USER FEEDBACK STATES THAT THE BRUSH HEAD OF A PROVOX BRUSH BROKE OFF DURING THE USUAL MORNING CLEANING ROUTINE WITHOUT ANY INDICATION OF DAMAGES BEFOREHAND. ACCORDING TO THE CUSTOMER, HE DID NEITHER BEND THE HANDLE NOR THE BRUSH HEAD TO FACILITATE EASIER CLEANING. FURTHERMORE HE STATES THAT HE VISUALLY INSPECTED THE BRUSH BEFORE USING AS STATED IN THE IFU. THE BRUSH HEAD OF THE PROVOX BRUSH CONSISTS OF NYLON FILAMENTS AS BRISTLES, TWISTED METAL WIRE (NAME: SUS304, DIAMETER: 0.65MM, STAINLESS STEEL) AND A PP-PLASTIC TIP ON TOP OF THE BRUSH HEAD. THIS STAINLESS STEEL WIRE HAS ITS BREAKING POINT AT 758 N/MM^2 ON AVERAGE, MAKING IT VERY RESILIENT TO MECHANICAL FORCES. IT REQUIRES REPEATED DAMAGE TO THE MATERIAL (SUCH AS BENDING IT BACK AND FORTH REPEATED) TO WEAKEN AND SUBSEQUENTLY BREAK THE MATERIAL. FURTHERMORE, SUS304 IS A MEDICAL GRADE STEEL USED IN A VARIETY OF MEDICAL PRODUCTS (SUCH AS IMPLANTS AND SURGICAL TOOLS). AS A CONSEQUENCE, THIS KIND OF STEEL HAS TO PASS VIGOROUS QUALITY CONTROLS. THE MAXIMUM FORCES APPLIED TO THE BRUSH DURING A CLEANING PROCEDURE ARE AT 13.7N (SOURCE: (B)(4), MAX. ESOPHAGEAL FLANGE STRENGTH). THE CHANCES OF DISLOCATING THE VOICE PROSTHESIS WHILE CLEANING ARE HIGH WHEN APPLYING MORE THAN 13.7N OF FORCE. THEREFORE, THE CUSTOMER WOULD HAVE DISLOCATED HIS VP BEFORE APPLYING ENOUGH FORCE TO DAMAGE THE BRUSH. TAKING ALL THOSE FACTS IN CONSIDERATION, IT IS HIGHLY LIKELY THAT THE BRUSH WAS SOMEHOW DAMAGED (BY BENDING, ETC.) BEFORE USAGE AS IT IS PHYSICALLY IMPOSSIBLE THAT THE MEDICAL-GRADE STEEL WIRE BROKE DURING A STANDARD CLEANING PROCEDURE. THE APPLIED FORCES ARE JUST TOO SMALL TO DAMAGE STEEL. THE CUSTOMER FURTHERMORE COMPLAINED ABOUT BRISTLES LOOSENING FROM THE BRUSH HEAD. THIS CAN HAPPEN WHEN THE BRUSH HEAD WAS DEFORMED AND BENT BACK AND WHEN THE BRUSH IS WORN OUT. THE ASSOCIATED RISK FOR THAT IS 2=NEGLIGIBLE AS NYLON FILAMENTS ARE JUST COUGHED OUT IF FALLEN DOWN THE TRACHEA. CONCLUSION: SINCE NO PRODUCT WAS RETURNED, WE WERE NOT ABLE TO SAFELY DETERMINE THE CAUSE OF THE FAILURE. THE DAMAGE TO THE PRODUCT IS MOST LIKELY CAUSED BY WRONG HANDLING OF THE PRODUCT. A DESIGN UPDATE OF PROVOX BRUSH IS UNDER DEVELOPMENT AND WILL BE MARKETED IN Q1 2019 ((B)(4)). THE PROVOX BRUSH WILL HAVE A SECOND TPE-LAYER AROUND THE METAL WIRE TO FURTHER PROTECT IT FROM TEMPERING AND DAMAGES. THIS IS AN INITIAL AND FINAL REPORT IN ONE.