MERSILENE SUTURE 12"(30CM) 5-0 WHT RS21

MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed from a literature report with the FDA on 2018-12-28 for MERSILENE SUTURE 12"(30CM) 5-0 WHT RS21 manufactured by Ethicon Inc..

Event Text Entries

[131707362] (b)(4). This report is related to a journal article, therefore no product will be returned for analysis and the batch history records cannot be reviewed as the lot number has not been provided. Citation: j. Obstet. Gynaecol. Res. Vol. 36, no. 1: 209? 212, february 2010; doi:10. 1111/j. 1447-0756. 2009. 01097. X. (b)(4).
Patient Sequence No: 1, Text Type: N, H10


[131707363] It was reported via journal article "title: translocation of a cerclage band into the endocervical canal after preconception transabdominal cervico-isthmic cerclage" authors: moon-il park and jeong-kyu hoh. Citation: j. Obstet. Gynaecol. Res. Vol. 36, no. 1: 209? 212, february 2010; doi:10. 1111/j. 1447-0756. 2009. 01097. X. This study aimed to present a (b)(6) year-old female patient who had history of five spontaneous losses and failure of two mcdonald purse-string cerclages, who underwent transabdominal cervico-isthmic cerclage (tcc) for incompetent cervix as a management of recurrent second-trimester pregnancy loss and preterm delivery. In the procedure, the posterior peritoneum was punctured with an aneurysm needle, passing a single strip of #5 mersilene band (0. 5 cm wide, mersilene 5, rs21, ethicon, inc. Nj, usa) from the posterior to the anterior side. The procedure then was repeated on the contralateral side using the same piece of mersilene band. The mersilene band was adjusted to lie flat over the posterior peritoneum at the level of the origin of the uterosacral ligaments. Then it was tied anteriorly causing compression without undue constriction of the intervening tissue. Her seventh pregnancy was uncomplicated, but a migration of about one third of the mersilene band was found into the cervical canal. Cerclage band was not removed as patient wanted further pregnancy. Her further pregnancy reached 33 weeks? Gestation due to preterm labor without any signs of infection. Both tubal ligations were performed, and the cerclage band was removed at this time. Although it could have been a case of pure coincidence of preterm labor, we take a chance to speculate that the migration of the cerclage band into the endocervical canal might have been the reason for the preterm labor.
Patient Sequence No: 1, Text Type: D, B5


MAUDE Entry Details

Report Number2210968-2018-78079
MDR Report Key8204371
Report SourceLITERATURE
Date Received2018-12-28
Date of Report2018-12-12
Date Mfgr Received2018-12-12
Date Added to Maude2018-12-28
Event Key0
Report Source CodeManufacturer report
Manufacturer LinkY
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag3
Health Professional3
Initial Report to FDA3
Report to FDA3
Event Location3
Manufacturer ContactDARLENE KYLE
Manufacturer StreetP.O. BOX 151, ROUTE 22 WEST
Manufacturer CitySOMERVILLE NJ 088760151
Manufacturer CountryUS
Manufacturer Postal088760151
Manufacturer Phone9082182792
Manufacturer G1ETHICON INC.
Single Use3
Previous Use Code3
Event Type3
Type of Report3

Device Details

Brand NameMERSILENE SUTURE 12"(30CM) 5-0 WHT
Generic NameCLASS I DEVICE - EXEMPT
Product CodeKDC
Date Received2018-12-28
Catalog NumberRS21
OperatorHEALTH PROFESSIONAL
Device AvailabilityN
Device Eval'ed by MfgrR
Device Sequence No1
Device Event Key0
ManufacturerETHICON INC.
Manufacturer AddressP.O. BOX 151, ROUTE 22 WEST SOMERVILLE NJ 088760151 US 088760151


Patients

Patient NumberTreatmentOutcomeDate
101. Required No Informationntervention 2018-12-28

© 2026 FDA.report
This site is not affiliated with or endorsed by the FDA.