SCISSORS "HIQ+", 5 X 330 MM, MINI-METZENBAUM, ERGO A63840A

MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed with the FDA on 2019-03-13 for SCISSORS "HIQ+", 5 X 330 MM, MINI-METZENBAUM, ERGO A63840A manufactured by Olympus Winter & Ibe Gmbh.

Event Text Entries

[139442672] Olympus followed up with the user facility via telephone and in writing to obtain additional regarding the patient, procedure and the concomitant devices that were used but no additional information was provided. The referenced device was not returned to olympus. The cause of the reported event could not be confirmed. However, if additional information becomes available or if the device is returned at a later date, this report will be supplemented accordingly.
Patient Sequence No: 1, Text Type: N, H10


[139442673] Olympus was informed that during an unspecified procedure the tip of the device melted off and fell inside the patient. The tip then fused with the patient. The staff brought in a surgeon to surgically remove the melted piece from the patient. It was also reported that the doctor had the electrosurgical generator turned to 100 watts for an hour. The patient outcome is unknown and it is unknown whether the melted piece was retrieved from the patient or not.
Patient Sequence No: 1, Text Type: D, B5


MAUDE Entry Details

Report Number2951238-2019-00532
MDR Report Key8417754
Date Received2019-03-13
Date of Report2019-03-13
Date of Event2019-02-20
Date Mfgr Received2019-02-20
Date Added to Maude2019-03-13
Event Key0
Report Source CodeManufacturer report
Manufacturer LinkY
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag3
Health Professional3
Initial Report to FDA3
Report to FDA3
Event Location3
Manufacturer ContactMS. CONNIE TUBERA
Manufacturer Street2400 RINGWOOD AVENUE
Manufacturer CitySAN JOSE CA 95131
Manufacturer CountryUS
Manufacturer Postal95131
Manufacturer Phone4089355124
Single Use3
Previous Use Code3
Event Type3
Type of Report0

Device Details

Brand NameSCISSORS "HIQ+", 5 X 330 MM, MINI-METZENBAUM, ERGO
Generic NameSCISSORS "HIQ+"
Product CodeHET
Date Received2019-03-13
Model NumberA63840A
Catalog NumberA63840A
OperatorHEALTH PROFESSIONAL
Device Availability*
Device Eval'ed by MfgrR
Device Sequence No1
Device Event Key0
ManufacturerOLYMPUS WINTER & IBE GMBH
Manufacturer AddressKUEHNSTRASSE 61 HAMBURG, HAMBURG 22045 GM 22045


Patients

Patient NumberTreatmentOutcomeDate
101. Required No Informationntervention 2019-03-13

© 2026 FDA.report
This site is not affiliated with or endorsed by the FDA.