CAPTURA PRO? BIOPSY FORCEPS WITH SPIKE BF-2.4SL-230SP-40

MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed from a company representative report with the FDA on 2019-03-26 for CAPTURA PRO? BIOPSY FORCEPS WITH SPIKE BF-2.4SL-230SP-40 manufactured by Cook Endoscopy.

Event Text Entries

[139886577] Initial reporter occupation: non-healthcare professional. Investigation evaluation: a product evaluation was not performed in response to this report because the product said to be involved was not provided to cook for evaluation. The customer provided two (2) photos of the bleeding site after biopsy was taken. Based on the photos provided by the user, the complaint is considered confirmed. A review of the device history record could not be conducted because the lot number was not provided. Investigation conclusion: we could not conduct a complete investigation because the product said to be involved was not returned for evaluation. A definitive cause for the reported observation could not be determined. The size of tissue sample or biopsy to be excised can be controlled by how the user handles the forceps. If excessive pressure was applied during advancement into the tissue or during handle manipulation, this could have contributed to the reported observation. The instructions for use (ifu) direct the user to,? Advance forceps to biopsy or retrieval site, then open cups and advance into tissue to be biopsied or object to be retrieved. Using slight pressure on handle, close forceps around tissue or object. . . . Maintain gentle handle pressure to keep cups closed and gently withdraw forceps from site.? The ifu warns, "these single-use biopsy forceps should only be used to biopsy tissue where possible bleeding or hemorrhage will not present a danger for patients. Adequate plans for management of potential bleeding or hemorrhage and appropriate airway management should be in place. " the ifu lists potential complications as, "those associated with gastrointestinal endoscopy include but are not limited to: perforation, bleeding or hemorrhage, aspiration, fever, infection, allergic reaction to medication, hypotension, respiratory depression or arrest, cardiac arrhythmia or arrest. " prior to distribution, all captura pro biopsy forceps with spike are subjected to a visual inspection to ensure device integrity. Corrective action: a review of the complaint history was conducted. The likelihood of occurrence is considered rare. Corrective action is not warranted at this time based on the quality engineering risk assessment. Quality assurance will continue to monitor for complaint trends and reassess the risk assessment results as post market feedback continues to become available.
Patient Sequence No: 1, Text Type: N, H10


[139886578] During colon biopsy procedures, the physician has used at least two (2) cook captura pro? Biopsy forceps with spike and indicated that the forceps cause too much bleeding, resulting in using more hemoclips [a general, recurring complaint]. The cook [district sales manager] has [provided] two (2) photos as an example (post-biopsy on a patient that is on blood thinners). The photos depict bleeding tissue. No sections of the devices remained inside the patients' bodies. The patients required additional hemoclips due to these occurrences. According to the initial reporter, the patients did not experience any adverse effects due to these occurrences.
Patient Sequence No: 1, Text Type: D, B5


MAUDE Entry Details

Report Number1037905-2019-00153
MDR Report Key8453014
Report SourceCOMPANY REPRESENTATIVE
Date Received2019-03-26
Date of Report2019-03-01
Date Mfgr Received2019-03-01
Date Added to Maude2019-03-26
Event Key0
Report Source CodeManufacturer report
Manufacturer LinkY
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag3
Health Professional3
Initial Report to FDA3
Report to FDA3
Event Location3
Manufacturer ContactMS. SCOTTIE FARIOLE
Manufacturer Street4900 BETHANIA STATION RD
Manufacturer CityWINSTON-SALEM NC 27105
Manufacturer CountryUS
Manufacturer Postal27105
Manufacturer Phone3367440157
Manufacturer G1COOK ENDOSCOPY
Manufacturer Street4900 BETHANIA STATION RD
Manufacturer CityWINSTON-SALEM NC 27105
Manufacturer CountryUS
Manufacturer Postal Code27105
Single Use3
Previous Use Code3
Event Type3
Type of Report3

Device Details

Brand NameCAPTURA PRO? BIOPSY FORCEPS WITH SPIKE
Generic NamePTS ENDOSCOPIC GRASPING/CUTTING INSTRUMENT, NON-POWERED, EXEMPT
Product CodePTS
Date Received2019-03-26
Catalog NumberBF-2.4SL-230SP-40
Lot NumberUNKNOWN
OperatorHEALTH PROFESSIONAL
Device AvailabilityN
Device Eval'ed by MfgrR
Device Sequence No1
Device Event Key0
ManufacturerCOOK ENDOSCOPY
Manufacturer Address4900 BETHANIA STATION RD WINSTON-SALEM NC 27105 US 27105


Patients

Patient NumberTreatmentOutcomeDate
101. Required No Informationntervention 2019-03-26