PULMONARY VALVE & CONDUIT SG SGPV00

MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed from a company representative,user f report with the FDA on 2019-03-29 for PULMONARY VALVE & CONDUIT SG SGPV00 manufactured by Cryolife, Inc..

Event Text Entries

[140283929] This investigation is currently ongoing. Any additional information will be provided in the follow-up report.
Patient Sequence No: 1, Text Type: N, H10


[140283930] According to the implant summary card, previously implanted cryolife tissue was explanted on (b)(6) 2019. Additional information received from the cryolife rep, indicates that a cryolife sgpv00 serial number (sn): (b)(4) was implanted on (b)(6) 2015. Additional information from karen krusinski, rn cardiac or team leader, relayed that the sgpv00 serial number (b)(4) was explanted on (b)(6) 2019 due to stenosis rv-pa conduit. The pre-op diagnosis for the procedure was stenosis rv-pa conduit, aortic atresia, vsd, s/p norwood, s/p rastelli. The procedure performed was pulmonary valve replacement. The patient was discharged home on (b)(6) 2019. No additional information.
Patient Sequence No: 1, Text Type: D, B5


MAUDE Entry Details

Report Number1063481-2019-00016
MDR Report Key8463775
Report SourceCOMPANY REPRESENTATIVE,USER F
Date Received2019-03-29
Date of Report2019-05-22
Date of Event2019-02-14
Date Mfgr Received2019-03-05
Date Added to Maude2019-03-29
Event Key0
Report Source CodeManufacturer report
Manufacturer LinkY
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag3
Health Professional3
Initial Report to FDA3
Report to FDA3
Event Location3
Manufacturer ContactROCHELLE MANEY
Manufacturer Street1655 ROBERTS BLVD. NW
Manufacturer CityKENNESAW GA 30144
Manufacturer CountryUS
Manufacturer Postal30144
Manufacturer Phone7704193355
Manufacturer G1CRYOLIFE, INC.
Manufacturer Street1655 ROBERTS BLVD. NW
Manufacturer CityKENNESAW GA 30144
Manufacturer CountryUS
Manufacturer Postal Code30144
Single Use3
Previous Use Code3
Event Type3
Type of Report3

Device Details

Brand NamePULMONARY VALVE & CONDUIT SG
Generic NameHEART VALVE, MORE THAN MINIMALLY MANIPULATED
Product CodeDXZ
Date Received2019-03-29
Model NumberSGPV00
Device AvailabilityN
Device Eval'ed by MfgrN
Device Sequence No1
Device Event Key0
ManufacturerCRYOLIFE, INC.
Manufacturer Address1655 ROBERTS BLVD. NW KENNESAW GA 30144 US 30144


Patients

Patient NumberTreatmentOutcomeDate
101. Other; 2. Required No Informationntervention 2019-03-29

© 2026 FDA.report
This site is not affiliated with or endorsed by the FDA.