VITROS CHEMISTRY PRODUCTS CKMB SLIDES 8058232

MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed with the FDA on 2019-04-01 for VITROS CHEMISTRY PRODUCTS CKMB SLIDES 8058232 manufactured by Ortho-clinical Diagnostics.

Event Text Entries

[143998399] The investigation determined that lower than expected vitros ck-mb results were obtained from multiple patient samples when run on a vitros 5600 integrated system. The results were considered lower compared to results obtained from the same samples tested using a non-vitros analyzer. The investigation was unable to determine the assignable cause of the event. The ortho technical solution center (tsc) was unable to obtain any other assay results or any specific clinical information regarding the patients. However, the customer reported the vitros ckmb results do not match the patient diagnosis. The tsc was unable to obtain any details regarding the pre-analytical sample collection, handling and storage of the samples used in the comparison and therefore, pre-analytical sample handling cannot be ruled out as a potential contributing factor. A review of quality control results for the month of february 2019 concluded that the performance of the vitros performance verifiers was acceptable; however, the quality control fluids were only processed 5-6 times the entire month of february. There are not enough qc data points processed in february 2019 to truly access the overall performance of the assay and therefore a ckmb lot 4940-0221-7109 issue cannot be ruled out as a contributing factor to this event. Continual tracking and trending of complaints has not identified any signals that would point to a potential systemic issue with this lot of vitros ckmb slides. The tsc requested the customer process within run precision testing to confirm performance of the reagent and the analyzer. The precision testing has not been completed at this time and an instrument issue cannot be ruled out as a contributor to this event.
Patient Sequence No: 1, Text Type: N, H10


[143998400] A customer obtained lower than expected vitros ck-mb results from multiple patient samples run on a vitros 5600 integrated system. The results were considered lower compared to results obtained from the same samples tested using a non-vitros analyzer. Sample 2 vitros = 5 u/l versus abbott architect 54 u/l. Sample 4 vitros = <3 u/l versus abbott architect 38 u/l. Sample 5 vitros = <3 u/l versus abbott architect 44 u/l. Sample 6 vitros = <3 u/l versus abbott architect 79 u/l. Sample 7 vitros = <3 u/l versus abbott architect 29 u/l. Biased results of the direction and magnitude observed may lead to inappropriate physician action if undetected. The lower than expected vitros ck-mb results were not reported from the laboratory. There was not allegation of actual patient harm as a result of this event. This report is number five of five mdr? S for this event. Five 3500a forms are being submitted for this event as a total of five devices were involved. This report corresponds to ortho clinical diagnostics inc (ortho). Complaint numbers (b)(4).
Patient Sequence No: 1, Text Type: D, B5


MAUDE Entry Details

Report Number1319809-2019-00021
MDR Report Key8470439
Date Received2019-04-01
Date of Report2019-04-01
Date of Event2019-02-26
Date Mfgr Received2019-03-05
Device Manufacturer Date2018-01-27
Date Added to Maude2019-04-01
Event Key0
Report Source CodeManufacturer report
Manufacturer LinkY
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag3
Health Professional3
Initial Report to FDA3
Report to FDA3
Event Location3
Manufacturer ContactMR. JAMES A STEVENS
Manufacturer Street100 INDIGO CREEK DRIVE
Manufacturer CityROCHESTER NY 14626
Manufacturer CountryUS
Manufacturer Postal14626
Manufacturer Phone5854533000
Manufacturer G1ORTHO-CLINICAL DIAGNOSTICS
Manufacturer Street513 TECHNOLOGY BLVD.
Manufacturer CityROCHESTER NY 14652
Manufacturer CountryUS
Manufacturer Postal Code14652
Single Use3
Previous Use Code3
Event Type3
Type of Report0

Device Details

Brand NameVITROS CHEMISTRY PRODUCTS CKMB SLIDES
Generic NameIN-VITRO DIAGNOSTIC
Product CodeJHS
Date Received2019-04-01
Catalog Number8058232
Lot Number4940-0221-7109
Device Expiration Date2019-07-01
Device AvailabilityY
Device Eval'ed by MfgrY
Device Sequence No1
Device Event Key0
ManufacturerORTHO-CLINICAL DIAGNOSTICS
Manufacturer Address100 INDIGO CREEK DRIVE ROCHESTER NY 14626 US 14626


Patients

Patient NumberTreatmentOutcomeDate
10 2019-04-01

© 2026 FDA.report
This site is not affiliated with or endorsed by the FDA.