PRESEP CENTRAL VENOUS OXIMETRY KIT X3820SJD

MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed from a company representative,foreig report with the FDA on 2019-04-05 for PRESEP CENTRAL VENOUS OXIMETRY KIT X3820SJD manufactured by Edwards Lifesciences.

Event Text Entries

[141100892] No product was returned for evaluation; it was discarded at the hospital. Without the return of the product, it is not possible to determine if damages or defects existed on the product. The lot number was not provided; therefore, a review of the manufacturing records could not be completed. No actions will be taken at this time. Invasive procedures involve some patient risks. Although serious complications are relatively uncommon, the physician is advised, before deciding to insert or use the catheter, to consider the potential benefits in relation to the possible complications. The techniques for insertion, methods of using the catheter to obtain patient data information, and the occurrence of complications is well described in the literature. In this case, the clinician commented that care of the insertion site was most likely a contributing factor to the development of the patient? S infection. Under the complications section of the ifu it states: positive catheter-tip cultures resulting from contamination and colonization have been reported, as well as incidences of septic and aseptic vegetation in the right heart. Increased risks of septicemia and bacteremia have been associated with blood sampling, infusion of fluids, and catheter-related thrombosis. Preventive measures should be taken to guard against infection (e. G. , use of sterile technique, application of topical antibiotic ointment, changing of sterile dressings as indicated by institutional policy, and disinfecting the injection caps before entry with syringe needle) as well as the frequent assessment of the continued need for hemodynamic monitoring. Complaint histories for all reported events are reviewed against trending control limits on a monthly basis, and any excursions above the control limits are assessed and documented as part of this monthly review.
Patient Sequence No: 1, Text Type: N, H10


[141100893] It was reported that a catheter-related infection was confirmed during use with a presep oximetry catheter after 15 days of use. Reportedly, the catheter was used during a pancreatoduodenectomy laparotomy for pancreas tumor in a (b)(6) male patient with a history of hypertension. The catheter was inserted via right internal jugular vein after general anesthesia. The catheter remained placed in the patient after surgery for total parenteral nutrition (tpn). The catheter was secured using suture loop and/or box clamp. On the 15th day of use, the patient suddenly developed shaking chills followed by a high fever of 39 degrees c. On the same day, samples were obtained from the catheter tip and blood cultures and staphylococcus epidermidis was detected from both culture results. The catheter was removed. The patient was given antibiotics: tazopip and sulacillin. The event resulted in extension of hospitalization but the patient's outcome was reported as? Recovered?. The clinician stated that the event was likely to be a retrograde infection rather than the infection due to procedural factors of catheter insertion, since the duration of the catheter placement was relatively long.
Patient Sequence No: 1, Text Type: D, B5


MAUDE Entry Details

Report Number2015691-2019-01200
MDR Report Key8487531
Report SourceCOMPANY REPRESENTATIVE,FOREIG
Date Received2019-04-05
Date of Report2019-03-13
Date of Event2018-10-04
Date Mfgr Received2019-03-13
Date Added to Maude2019-04-05
Event Key0
Report Source CodeManufacturer report
Manufacturer LinkY
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag3
Health Professional3
Initial Report to FDA3
Report to FDA3
Event Location3
Manufacturer ContactMS. LYNN THOMAS
Manufacturer Street1 EDWARDS WAY
Manufacturer CityIRVINE CA 92614
Manufacturer CountryUS
Manufacturer Postal92614
Manufacturer Phone9497564386
Manufacturer G1EDWARDS LIFESCIENCES, PR
Manufacturer StreetSTATE RD INDUS PK 402 KM 1.4
Manufacturer CityANASCO PR 00610
Manufacturer CountryUS
Manufacturer Postal Code00610
Single Use3
Previous Use Code3
Event Type3
Type of Report3

Device Details

Brand NamePRESEP CENTRAL VENOUS OXIMETRY KIT
Generic NamePRESEP CATHETER
Product CodeDQE
Date Received2019-04-05
Model NumberX3820SJD
OperatorHEALTH PROFESSIONAL
Device AvailabilityN
Device Eval'ed by Mfgr*
Device Sequence No1
Device Event Key0
ManufacturerEDWARDS LIFESCIENCES
Manufacturer AddressSTATE RD INDUS PK 402 KM 1.4 ANASCO PR 00610 US 00610


Patients

Patient NumberTreatmentOutcomeDate
101. Hospitalization; 2. Required No Informationntervention 2019-04-05