EDWARDS COMMANDER DELIVERY SYSTEM 9600LDS26A

MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed with the FDA on 2019-04-17 for EDWARDS COMMANDER DELIVERY SYSTEM 9600LDS26A manufactured by Edwards Lifesciences.

Event Text Entries

[142665886] (b)(4). Investigation is ongoing.
Patient Sequence No: 1, Text Type: N, H10


[142665887] As reported, during a mitral valve in valve procedure (26mm s3 in 25mm surgical valve) via transseptal approach, the commander delivery system balloon burst once it reached full inflation. The valve was deployed as intended with mild to moderate pvl noted post deployment. Upon removal of the delivery system, the balloon was unable to inserted back into the esheath. The delivery system and esheath were then removed as a unit and a second esheath was inserted into the patient. A non ew balloon was used to dilate the valve, which reduced the pvl grade to none-trace. The patient left the room in stable condition.
Patient Sequence No: 1, Text Type: D, B5


MAUDE Entry Details

Report Number2015691-2019-01343
MDR Report Key8522749
Date Received2019-04-17
Date of Report2019-03-27
Date of Event2019-03-27
Date Mfgr Received2019-05-16
Device Manufacturer Date2018-11-16
Date Added to Maude2019-04-17
Event Key0
Report Source CodeManufacturer report
Manufacturer LinkY
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag3
Health Professional3
Initial Report to FDA3
Report to FDA3
Event Location3
Manufacturer ContactRN FRANCES PRESTON
Manufacturer Street1 EDWARDS WAY
Manufacturer CityIRVINE CA 92614
Manufacturer CountryUS
Manufacturer Postal92614
Manufacturer Phone9492505190
Manufacturer G1EDWARDS LIFESCIENCES LLC
Manufacturer StreetONE EDWARDS WAY
Manufacturer CityIRVINE CA 92614
Manufacturer CountryUS
Manufacturer Postal Code92614
Single Use3
Previous Use Code3
Event Type3
Type of Report0

Device Details

Brand NameEDWARDS COMMANDER DELIVERY SYSTEM
Generic NamePROSTHESIS, MITRAL VALVE, PERCUTANEOUSLY DELIVERED
Product CodeNPU
Date Received2019-04-17
Model Number9600LDS26A
Lot Number61757101
OperatorHEALTH PROFESSIONAL
Device AvailabilityN
Device AgeDA
Device Eval'ed by MfgrN
Device Sequence No1
Device Event Key0
ManufacturerEDWARDS LIFESCIENCES
Manufacturer AddressONE EDWARDS WAY IRVINE CA 92614 US 92614


Patients

Patient NumberTreatmentOutcomeDate
10 2019-04-17

© 2026 FDA.report
This site is not affiliated with or endorsed by the FDA.