EXACT COUCH NA

MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed from a 01,06 report with the FDA on 2007-10-19 for EXACT COUCH NA manufactured by Varian Medical Systems.

Event Text Entries

[734870] Operator a was holding the couch at the back of couch top- fingers in-between the tabletop edge and movable carbon fiber rail. Operator b was assisting in moving the couch top with pt loaded in the longitudinal direction. With operator a's first fingers in the location stated above, a pinch point existed between the moving carriage and the stationary lateral base. The couch top was moved in towards the stand too fast and broke the bone on the finger of therapist a.
Patient Sequence No: 1, Text Type: D, B5


[8120590] This incident is recognized as use error by varian medical systems. Labeling placed on the couch, as well as in the user manual, provide instruction and hazard warnings (with respect to hand placement), which help to ensure the safe operation of the equipment. However, capa has been opened to investigate possible product improvement to further mitigate this documented risk.
Patient Sequence No: 1, Text Type: N, H10


MAUDE Entry Details

Report Number2914292-2007-00039
MDR Report Key930043
Report Source01,06
Date Received2007-10-19
Date of Report2007-10-08
Date of Event2007-10-08
Date Mfgr Received2007-10-11
Device Manufacturer Date1997-03-01
Date Added to Maude2007-10-25
Event Key0
Report Source CodeManufacturer report
Manufacturer LinkY
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag3
Health Professional3
Initial Report to FDA3
Report to FDA0
Event Location0
Manufacturer ContactDALE REYNOLDS
Manufacturer Street911 HANSEN WAY
Manufacturer CityPALO ALTO CA 95117
Manufacturer CountryUS
Manufacturer Postal95117
Manufacturer Phone6504246640
Single Use3
Previous Use Code3
Event Type3
Type of Report3

Device Details

Brand NameEXACT COUCH
Generic NamePATIENT POSITIONING TABLE
Product CodeJAI
Date Received2007-10-19
Model NumberEXACT COUCH
Catalog NumberNA
Lot NumberNA
Device AvailabilityY
Device AgeDA
Device Eval'ed by MfgrY
Implant FlagN
Date RemovedB
Device Sequence No1
Device Event Key904306
ManufacturerVARIAN MEDICAL SYSTEMS
Manufacturer Address3100 HANSEN WAY PALO ALTO CA 94304 US


Patients

Patient NumberTreatmentOutcomeDate
10 2007-10-19

© 2026 FDA.report
This site is not affiliated with or endorsed by the FDA.