UNKNOWN_NEUWAVE

MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed from a literature report with the FDA on 2019-12-20 for UNKNOWN_NEUWAVE manufactured by Neuwave Medical, Inc..

Event Text Entries

[187165472] (b)(4). Date of event: publication year of 2013. This report is related to a journal article, therefore no product will be returned for analysis and the lot history records cannot be reviewed as the lot number has not been provided. (b)(4).
Patient Sequence No: 1, Text Type: N, H10


[187165473] It was reported via literature entitled: percutaneous hepatic microwave ablation with high-powered, gas cooled antennas: short term results in 87 patients authors: ziemlewicz t. , hinshaw j. , lubner m. , brace c. , sampson l. , center m. Citation: journal of vascular and interventional radiology. 2013 jan; conference: symposium on clinical interventional oncology, cio 2013. Miami beach, fl united states. 24 (1) :145. E31-145. E32. The purpose of this retrospective study was to review the results in the first 87 patients with malignant hepatic tumors treated with a new high-power, gas-cooled microwave (mw) ablation device. Between december 2010 and september 2012, 87 patients were enrolled in the study. All procedures were performed with a high-powered, gas-cooled microwave system (certus 140, neuwave medical, madison, wi) utilizing 1-3 17-gauge antennas. Reported complication included right pleural effusion (n=2) requiring thoracentesis for symptomatic relief; portal vein clot (n=1) requiring anti-coagulation. In conclusion, early experience treating liver tumors using a high-powered, gas-cooled microwave ablation system demonstrates excellent local control with minimal complications.
Patient Sequence No: 1, Text Type: D, B5


MAUDE Entry Details

Report Number3008769756-2019-00055
MDR Report Key9503398
Report SourceLITERATURE
Date Received2019-12-20
Date of Report2019-12-02
Date of Event2013-01-01
Date Mfgr Received2019-12-02
Date Added to Maude2019-12-20
Event Key0
Report Source CodeManufacturer report
Manufacturer LinkY
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag3
Health Professional3
Initial Report to FDA3
Report to FDA3
Event Location3
Manufacturer ContactMS. KARA DITTY-BOVARD
Manufacturer Street3529 ANDERSON ST
Manufacturer CityMADISON 53704
Manufacturer CountryUS
Manufacturer Postal53704
Manufacturer Phone6107428552
Manufacturer G1NEUWAVE MEDICAL, INC.
Manufacturer Street3529 ANDERSON ST
Manufacturer CityMADISON 53704
Manufacturer CountryUS
Manufacturer Postal Code53704
Single Use3
Previous Use Code3
Event Type3
Type of Report3

Device Details

Brand NameUNKNOWN_NEUWAVE
Generic NameSYSTEM, ABLATION, MICROWAVE AND ACCESSORIES
Product CodeNEY
Date Received2019-12-20
Catalog NumberUNKNOWN_NEUWAVE
OperatorHEALTH PROFESSIONAL
Device AvailabilityN
Device Eval'ed by MfgrR
Device Sequence No1
Device Event Key0
ManufacturerNEUWAVE MEDICAL, INC.
Manufacturer Address3529 ANDERSON ST MADISON 53704 US 53704


Patients

Patient NumberTreatmentOutcomeDate
101. Required No Informationntervention 2019-12-20