DAILIES TOTAL 1 CBV92004051

MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed from a foreign,other report with the FDA on 2020-01-02 for DAILIES TOTAL 1 CBV92004051 manufactured by Alcon Research, Llc.

Event Text Entries

[188836084] The complaint sample has not returned for evaluation. Investigation including root cause analysis is in progress. A supplemental mdr will be filed as necessary in accordance with 21 cfr 803. 56 when additional reportable information becomes available. The manufacturer internal reference number is: (b)(4).
Patient Sequence No: 1, Text Type: N, H10


[188836085] It was reported on (b)(6) 2019, that a consumer had to throw out a couple of lenses due to it not being clear. Additional information was received on 12dec2019 clarifying that the lenses were only blurry once placed on the eye. It was also reported that the lenses did not sit correctly on the eye after an hour or so and would therefore cause irritation. It was reported that the consumer suffered from a corneal ulcer resulting to the need to seek medical help and the consumer had to go to a number of appointments and an emergency specialist. Treatment modality, duration and eye involvement was not disclosed. The corneal ulcer has resolved leaving only minor scarring and the consumer is able to wear lenses again.
Patient Sequence No: 1, Text Type: D, B5


MAUDE Entry Details

Report Number1065835-2020-00001
MDR Report Key9537579
Report SourceFOREIGN,OTHER
Date Received2020-01-02
Date of Report2020-01-24
Date of Event2019-06-28
Date Mfgr Received2020-01-03
Device Manufacturer Date2019-01-23
Date Added to Maude2020-01-02
Event Key0
Report Source CodeManufacturer report
Manufacturer LinkY
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag3
Health Professional3
Initial Report to FDA3
Report to FDA3
Event Location3
Manufacturer ContactMR. JASON MICHAELIDES
Manufacturer Street6201 SOUTH FREEWAY MAIL STOP AB2-6
Manufacturer CityFORT WORTH TX 76134
Manufacturer CountryUS
Manufacturer Postal76134
Manufacturer Phone8175686438
Manufacturer G1ALCON RESEARCH, LLC
Manufacturer Street11440 JOHNS CREEK PARKWAY
Manufacturer CityDULUTH GA 30097
Manufacturer CountryUS
Manufacturer Postal Code30097
Single Use3
Previous Use Code3
Removal Correction NumberNA
Event Type3
Type of Report3

Device Details

Brand NameDAILIES TOTAL 1
Generic NameLENSES, SOFT CONTACT, DAILY WEAR
Product CodeLPL
Date Received2020-01-02
Model NumberNA
Catalog NumberCBV92004051
Lot NumberA5057878
OperatorLAY USER/PATIENT
Device AvailabilityN
Device AgeDA
Device Eval'ed by MfgrR
Device Sequence No1
Device Event Key0
ManufacturerALCON RESEARCH, LLC
Manufacturer Address11440 JOHNS CREEK PARKWAY DULUTH GA 30097 US 30097


Patients

Patient NumberTreatmentOutcomeDate
101. Other 2020-01-02