GM85

MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed from a company representative,user f report with the FDA on 2020-01-20 for GM85 manufactured by Samsung Electronics Co., Ltd..

Event Text Entries

[177344878] Operator mentioned that when she moved the gm85 backwards it did not stop and pinned her against the wall. She was able to slip out from behind the machine. When the elevator ride was over, the machine worked normally without issue. Our service representative checked the machine after the incident, drove it around and tried to reproduce the issue, checked calibration and settings. The noted malfunction was not reproducible as the system did not show anything to be out of the ordinary. The operator felt confident enough to continue using the gm85 system.
Patient Sequence No: 1, Text Type: N, H10


[177344879] Gm85 operator was pinned against the wall of the elevator that was being used to transport said system to another floor. The system apparently did not stop moving backwards against the operator when it was initially set in that motion to do so, which then pinned said operator. This backwards movement was being done to allow for additional space to be utilized inside the elevator.
Patient Sequence No: 1, Text Type: D, B5


MAUDE Entry Details

Report Number3010300212-2020-00001
MDR Report Key9608483
Report SourceCOMPANY REPRESENTATIVE,USER F
Date Received2020-01-20
Date of Report2020-01-20
Date of Event2020-01-02
Date Facility Aware2020-01-02
Report Date2020-01-20
Date Reported to FDA2020-01-20
Date Reported to Mfgr2020-01-07
Date Mfgr Received2020-01-07
Date Added to Maude2020-01-20
Event Key0
Report Source CodeManufacturer report
Manufacturer LinkY
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag3
Reporter OccupationOTHER HEALTH CARE PROFESSIONAL
Health Professional3
Initial Report to FDA3
Report to FDA3
Event Location3
Manufacturer ContactDR. NINAD GUJAR
Manufacturer Street14 ELECTRONICS AVENUE
Manufacturer CityDANVERS MA 01923
Manufacturer CountryUS
Manufacturer Postal01923
Manufacturer Phone9785648632
Manufacturer G1SAMSUNG ELECTRONICS CO., LTD.
Manufacturer Street129, SAMSUNG-RO, YEONGTONG-GU
Manufacturer CitySUWON-SI, GYEONGGIDO 16677
Manufacturer CountryKS
Manufacturer Postal Code16677
Single Use3
Previous Use Code3
Event Type3
Type of Report3

Device Details

Brand NameGM85
Generic NameDIGITAL DIAGNOSTIC MOBILE X-RAY SYSTEM
Product CodeIZL
Date Received2020-01-20
Model NumberGM85
Device AvailabilityN
Device Eval'ed by MfgrY
Device Sequence No1
Device Event Key0
ManufacturerSAMSUNG ELECTRONICS CO., LTD.
Manufacturer Address129, SAMSUNG-RO, YEONGTONG-GU SUWON-SI, 16677 KS 16677


Patients

Patient NumberTreatmentOutcomeDate
101. Hospitalization 2020-01-20

© 2026 FDA.report
This site is not affiliated with or endorsed by the FDA.