SWAB ALCOHOL 100 BX 1200 ASIA PACIFIC 326894

MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed from a consumer,foreign,other report with the FDA on 2020-01-28 for SWAB ALCOHOL 100 BX 1200 ASIA PACIFIC 326894 manufactured by Bd Medical - Diabetes Care.

Event Text Entries

[183797654] Investigation summary: level a investigation - complaint evaluation / complaint history check for the event(s) that occurred. Severity: s_1__; occurrence: a complaint history check was performed and this is the 1st related complaint for foreign matter (brown tape) on lot # 9261602. Investigation summary: customer returned three (3) used bd alcohol swabs from lot 9261602 (two from line 6 and one from line 5). Consumer reported the brown tape was found. All three returned swabs were examined, and it was observed that splicing tape was attached all three of the swabs. Manufacturing (holdrege) will be notified of the observed issue. A review of the device history record was completed for batch #9261602. All inspections were performed per the applicable operations qc specifications. There were zero (0) notifications noted that pertained to the complaint. Investigation conclusion: based on the samples and/or photo(s) received the investigation concluded: confirmed: bd was able to duplicate or confirm the customer? S indicated failure (splicing tape on swabs). Complaints received for this device and reported condition will continue to be tracked and trended. Information will be captured on trend reports and monitored monthly. Our business team regularly reviews the collected data for identification of emerging trends. Root cause description: as per investigation completed by manufacturing under investigation child (b)(4), "on 23jan2020, holdrege received a photo of fm on the pad from a bd alcohol swab from batch 9261602 material 326894 a visual evaluation of the swabs found splicing tape across one end of the pad. The swabs were produced on 29sep2019? 03oct2019 on the circles operation. Process: at the swab machines, every pad roll is spliced together with? Brown? Tape like what is seen in the complaint. The tape is manually applied, by the swab associate, onto the end of the pad roll that is on the machine onto the new pad roll that is being introduced. An eye (sick eye) on each side of the pad roll (lane 1 & lane 10) is used to detect the taped splice. When the eye detects the slice, it counts (so many cycles) and automatically rejects the swabs, prior to the carton an accumulator into a waste bin. Investigation: the dhr, l2l dispatches, logbooks and quality notifications were all reviewed. Nothing was found pertaining to this type of complaint. No definitive root cause can be determined. Root cause: root cause for this defect cannot be determined. Complaints received for this device and reported condition will continue to be tracked and trended. Information will be captured on trend reports and monitored. Our business team regularly reviews the collected data for identification of emerging trends. " rationale: based on the investigation, no additional investigation and no capa is required at this time.
Patient Sequence No: 1, Text Type: N, H10


[183797655] It was reported that swab alcohol 100 bx 1200 asia pacific had foreign material on it. This occurred on 5 occasions before use. The following information was provided by the initial reporter: the brown tape was found.
Patient Sequence No: 1, Text Type: D, B5


MAUDE Entry Details

Report Number1920898-2020-00041
MDR Report Key9635851
Report SourceCONSUMER,FOREIGN,OTHER
Date Received2020-01-28
Date of Report2020-01-16
Date of Event2020-01-14
Date Mfgr Received2020-01-15
Device Manufacturer Date2019-09-18
Date Added to Maude2020-01-28
Event Key0
Report Source CodeManufacturer report
Manufacturer LinkY
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag3
Reporter OccupationOTHER HEALTH CARE PROFESSIONAL
Health Professional3
Initial Report to FDA3
Report to FDA3
Event Location3
Manufacturer ContactBDX BRETT WILKO
Manufacturer Street9450 SOUTH STATE STREET
Manufacturer CitySANDY UT 84070
Manufacturer CountryUS
Manufacturer Postal84070
Manufacturer Phone8015652341
Manufacturer G1BD MEDICAL - DIABETES CARE
Manufacturer Street1329 WEST HIGHWAY 6
Manufacturer CityHOLDREGE NE 68949
Manufacturer CountryUS
Manufacturer Postal Code68949
Single Use3
Previous Use Code3
Event Type3
Type of Report3

Device Details

Brand NameSWAB ALCOHOL 100 BX 1200 ASIA PACIFIC
Generic NameALCOHOL SWAB
Product CodeLKB
Date Received2020-01-28
Returned To Mfg2020-01-23
Catalog Number326894
Lot Number9261602
OperatorLAY USER/PATIENT
Device AvailabilityR
Device Eval'ed by MfgrY
Device Sequence No1
Device Event Key0
ManufacturerBD MEDICAL - DIABETES CARE
Manufacturer Address1329 WEST HIGHWAY 6 HOLDREGE NE 68949 US 68949


Patients

Patient NumberTreatmentOutcomeDate
101. Other 2020-01-28