INTERPULSE HANDPIECE WITH DUAL SPIKE ADAPTER AND HIGH FLOW TIP 0210166000

MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed from a company representative report with the FDA on 2020-01-28 for INTERPULSE HANDPIECE WITH DUAL SPIKE ADAPTER AND HIGH FLOW TIP 0210166000 manufactured by Stryker Instruments-puerto Rico.

Event Text Entries

[177193781] This record is a consolidation of records summarized as a part of the fda voluntary malfunction summary reporting program. Reported events: 1 event was reported for this quarter. Product return status: 1 device was evaluated in the field. Event confirmation status: 1 reported event was confirmed. Evaluation results: 1 device was found to be affected by an issue with manufacturing. Additional information: 1 device was labeled for single-use. 1 device was not reprocessed or reused.
Patient Sequence No: 1, Text Type: N, H10


[177193782] This report summarizes 1 malfunction event in which the device had debris in sterile package. 1 event had patient involvement; no patient impact.
Patient Sequence No: 1, Text Type: D, B5


MAUDE Entry Details

Report Number0001811755-2020-00139
MDR Report Key9636420
Report SourceCOMPANY REPRESENTATIVE
Date Received2020-01-28
Date of Report2020-01-28
Date of Event2019-12-31
Date Mfgr Received2019-12-31
Date Added to Maude2020-01-28
Event Key0
Report Source CodeManufacturer report
Manufacturer LinkY
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag3
Health Professional3
Initial Report to FDA3
Report to FDA3
Event Location3
Manufacturer ContactMR. ZACH BAKER
Manufacturer Street4100 EAST MILHAM AVENUE
Manufacturer CityKALAMAZOO MI 49001
Manufacturer CountryUS
Manufacturer Postal49001
Manufacturer Phone2693237700
Manufacturer G1STRYKER INSTRUMENTS-KALAMAZOO
Manufacturer Street4100 EAST MILHAM AVENUE
Manufacturer CityKALAMAZOO MI 49001
Manufacturer CountryUS
Manufacturer Postal Code49001
Single Use3
Previous Use Code3
Event Type3
Type of Report3

Device Details

Brand NameINTERPULSE HANDPIECE WITH DUAL SPIKE ADAPTER AND HIGH FLOW TIP
Generic NameLAVAGE, JET
Product CodeFQH
Date Received2020-01-28
Catalog Number0210166000
Lot NumberVMSR
Device AvailabilityN
Device Eval'ed by MfgrR
Device Sequence No1
Device Event Key0
ManufacturerSTRYKER INSTRUMENTS-PUERTO RICO
Manufacturer AddressLAS PALMAS INDUSTRIAL PARK HIGHWAY #3, KM 130.2 ARROYO 00615 PR 00615


Patients

Patient NumberTreatmentOutcomeDate
10 2020-01-28