MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed from a company representative,health report with the FDA on 2020-02-07 for 4 LESION NT2000? PAIN MANAGEMENT RF GENERATOR RFG-NT-2000 manufactured by St. Jude Medical, Inc..
[178218938]
During a lumbar ablation procedure, the generator would not increase temperature and the procedure was cancelled. The probes would not exceed 37 degrees so stagger start was attempted, a different adapter was used, and the grounding pad was replaced with no resolution. Impedance remained between 200-400 ohms. The probes were reading temperature but would not increase in temperature when auto start was pressed and the procedure was rescheduled. There were no adverse consequences to the patient due to the cancellation.
Patient Sequence No: 1, Text Type: D, B5
Report Number | 2184149-2020-00008 |
MDR Report Key | 9683628 |
Report Source | COMPANY REPRESENTATIVE,HEALTH |
Date Received | 2020-02-07 |
Date of Report | 2020-02-07 |
Date of Event | 2020-01-13 |
Date Mfgr Received | 2020-01-13 |
Device Manufacturer Date | 2019-11-11 |
Date Added to Maude | 2020-02-07 |
Event Key | 0 |
Report Source Code | Manufacturer report |
Manufacturer Link | Y |
Number of Patients in Event | 0 |
Adverse Event Flag | 3 |
Product Problem Flag | 3 |
Reprocessed and Reused Flag | 3 |
Health Professional | 3 |
Initial Report to FDA | 3 |
Report to FDA | 3 |
Event Location | 3 |
Manufacturer Contact | STEPHANIE O' SULLIVAN |
Manufacturer Street | 5050 NATHAN LANE NORTH |
Manufacturer City | PLYMOUTH MN 55442 |
Manufacturer Country | US |
Manufacturer Postal | 55442 |
Manufacturer Phone | 6517565400 |
Manufacturer G1 | ST. JUDE MEDICAL, INC. |
Manufacturer Street | ONE ST. JUDE MEDICAL DRIVE |
Manufacturer City | ST. PAUL MN 55117 |
Manufacturer Country | US |
Manufacturer Postal Code | 55117 |
Single Use | 3 |
Previous Use Code | 3 |
Event Type | 3 |
Type of Report | 3 |
Brand Name | 4 LESION NT2000? PAIN MANAGEMENT RF GENERATOR |
Generic Name | GENERATOR, LESION, RADIOFREQUENCY |
Product Code | GXD |
Date Received | 2020-02-07 |
Returned To Mfg | 2020-02-06 |
Model Number | RFG-NT-2000 |
Catalog Number | RFG-NT-2000 |
Lot Number | 7248337 |
Operator | HEALTH PROFESSIONAL |
Device Availability | R |
Device Eval'ed by Mfgr | R |
Device Sequence No | 1 |
Device Event Key | 0 |
Manufacturer | ST. JUDE MEDICAL, INC. |
Manufacturer Address | ONE ST. JUDE MEDICAL DRIVE ST. PAUL MN 55117 US 55117 |
Patient Number | Treatment | Outcome | Date |
---|---|---|---|
1 | 0 | 1. Other | 2020-02-07 |