SIMULUS FULLY FLEXIBLE ANNULOPLASTY BAND 700FC27

MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed from a company representative,health report with the FDA on 2020-02-11 for SIMULUS FULLY FLEXIBLE ANNULOPLASTY BAND 700FC27 manufactured by Medtronic Heart Valves Division.

Event Text Entries

[182594333] Product analysis: no product was returned. Conclusion: without the return of the product, no definitive conclusion can be made regarding the clinical observation. If information is provided in the future, a supplemental report will be issued.
Patient Sequence No: 1, Text Type: N, H10


[182594434] Medtronic received information that during the repair of the patient's native mitral valve due to severe regurgitation, the native valve was noted to have diminutive leaflets as well as leaflet perforation following what appeared to be healed endocarditis. The surgeon performed various suturing repairs to the mitral valve, but the valve still had regurgitation. Subsequently, this 27mm mitral annuloplasty band was implanted. It was reported that the regurgitation improved, however, residual regurgitation remained. As such the 27mm band was explanted and replaced with a 25mm band of the same model. No additional adverse patient effects were reported.
Patient Sequence No: 1, Text Type: D, B5


MAUDE Entry Details

Report Number2025587-2020-00429
MDR Report Key9691266
Report SourceCOMPANY REPRESENTATIVE,HEALTH
Date Received2020-02-11
Date of Report2020-02-10
Date of Event2019-12-18
Date Mfgr Received2020-01-16
Date Added to Maude2020-02-11
Event Key0
Report Source CodeManufacturer report
Manufacturer LinkY
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag3
Health Professional3
Initial Report to FDA3
Report to FDA3
Event Location3
Manufacturer ContactPAULA BIXBY
Manufacturer Street8200 CORAL SEA STREET NE
Manufacturer CityMOUNDS VIEW MN 55112
Manufacturer CountryUS
Manufacturer Postal55112
Manufacturer Phone7635055378
Manufacturer G1MEDTRONIC HEART VALVES DIVISION
Manufacturer Street1851 E DEERE AVE
Manufacturer CitySANTA ANA CA 92705
Manufacturer CountryUS
Manufacturer Postal Code92705
Single Use3
Previous Use Code3
Event Type3
Type of Report3

Device Details

Brand NameSIMULUS FULLY FLEXIBLE ANNULOPLASTY BAND
Generic NameRING, ANNULOPLASTY
Product CodeKRH
Date Received2020-02-11
Model Number700FC27
Catalog Number700FC27
OperatorHEALTH PROFESSIONAL
Device AvailabilityN
Device Eval'ed by Mfgr*
Device Sequence No1
Device Event Key0
ManufacturerMEDTRONIC HEART VALVES DIVISION
Manufacturer Address1851 E DEERE AVE SANTA ANA CA 92705 US 92705


Patients

Patient NumberTreatmentOutcomeDate
101. Required No Informationntervention 2020-02-11