MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed from a company representative report with the FDA on 2020-03-19 for FMP 932-44-760 manufactured by Encore Medical L.p.
[184250756]
The reason for this revision surgery was reported as an infection. The previous surgery and the surgery detailed in this event occurred 9 days apart. The healthcare professional indicated there was no delay in surgery and another suitable device was available for use. The revision surgery was completed as intended. The devices were disposed of at hospital and not made available to djo surgical for examination. A review of the device history records show that the reported components used in the previous surgery, when released for use, met design and manufacturing requirements. There was a ncmr# 53379 item: 425-96-007 lot quantity-12, sample quantity-0, reject quantity-1, failure code-v18-porous coating visual p2, cause code-un01 - unknown, revision found-d, defect description- 1 part has porous coating contamination. Did not come out after cleanline, specification requirements- 2000. 2184, disposition-rework, justification- soda blast via spar(1000. 3019. 12). The devices were verified to have gone through an acceptable sterilization process and were within its expiration date at the time of the previous surgery. Customer complaint history of the reported devices showed no present trends or on-going issues that are needing a review. The root cause of this complaint was reported as an infection. There were no findings during this evaluation that indicate that the reported devices were the source or had a direct connection with the patient's infection. No information was submitted with the complaint regarding pre-existing conditions of the patient or any activities the patient was involved in that may have contributed to the possible infection or inhibited the patient's immune system. Due to the short time between the original surgery and the revision, it is possible that the infection was acquired in the hospital (nosocomial). It is also possible that the patient was not compliant with post surgical instructions. There are multiple factors that may contribute to an infection that are outside the control of djo surgical. There are no indications of a product or process issue affecting implant safety or effectiveness.
Patient Sequence No: 1, Text Type: N, H10
[184250757]
Revision surgery - infection, wash out.
Patient Sequence No: 1, Text Type: D, B5
Report Number | 1644408-2020-00205 |
MDR Report Key | 9854013 |
Report Source | COMPANY REPRESENTATIVE |
Date Received | 2020-03-19 |
Date of Report | 2020-03-17 |
Date of Event | 2020-02-19 |
Date Mfgr Received | 2020-02-19 |
Device Manufacturer Date | 2019-12-18 |
Date Added to Maude | 2020-03-19 |
Event Key | 0 |
Report Source Code | Manufacturer report |
Manufacturer Link | Y |
Number of Patients in Event | 0 |
Adverse Event Flag | 3 |
Product Problem Flag | 3 |
Reprocessed and Reused Flag | 3 |
Health Professional | 3 |
Initial Report to FDA | 3 |
Report to FDA | 3 |
Event Location | 3 |
Manufacturer Contact | TEFFANY HUTTO |
Manufacturer Street | 9800 METRIC BLVD |
Manufacturer City | AUSTIN, TX 78758-5445 |
Manufacturer Country | US |
Manufacturer G1 | ENCORE MEDICAL L.P |
Manufacturer Street | 9800 METRIC BLVD |
Manufacturer City | AUSTIN, TX 78758-5445 |
Manufacturer Country | US |
Single Use | 3 |
Previous Use Code | 3 |
Event Type | 3 |
Type of Report | 3 |
Brand Name | FMP |
Generic Name | LINER 10 DEG HOODED-NEU, MP10, HXE-PLUS, 44MM |
Product Code | OQG |
Date Received | 2020-03-19 |
Model Number | 932-44-760 |
Catalog Number | 932-44-760 |
Lot Number | 816N1967 |
Operator | HEALTH PROFESSIONAL |
Device Availability | N |
Device Eval'ed by Mfgr | R |
Device Sequence No | 1 |
Device Event Key | 0 |
Manufacturer | ENCORE MEDICAL L.P |
Manufacturer Address | 9800 METRIC BLVD AUSTIN, TX 78758-5445 US |
Patient Number | Treatment | Outcome | Date |
---|---|---|---|
1 | 0 | 1. Required No Informationntervention | 2020-03-19 |