SPECTRA OPTIA 10220

MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed from a foreign,health professional,l report with the FDA on 2020-03-20 for SPECTRA OPTIA 10220 manufactured by Terumo Bct.

Event Text Entries

[188575802] Lot number and expiry information are not available at this time investigation: per the article, the reactions occurred in the following patients: trali in a myasthenic patient, hypotension possibly due to allergic reaction in a patient with vasculitis and cardiac arrest in a patient with mixed connective tissue disease. On the authors' follow up for the article, patients showed clinical improvement. Per the article, "patients were classified into 4 categories as per the 2010 guidelines of american society for apheresis (asfa). Category i included indications where apheresis is accepted as a first line therapy; category ii when apheresis is accepted either as a solitary treatment or in conjunction with other treatment(s); category iii included disorders in which optimum role of apheresis therapy has not been established and category iv when published evidence demonstrates ineffectiveness or harm from apheresis... Tpe was performed for category i indications in 50%, category ii in 20%, category iii in 7% and category iv in 23% patients... The volume exchanged was as per the standard prescription for the indication in each category, as recommended by asfa guidelines. Fresh frozen plasma (ffp), isotonic crystalloids, cryo poor plasma and packed red cells constituted 62. 9%, 22%, 9. 9% and 5. 3% of plasma volume replacement respectively. " the technique they used was similar to that used in other studies. The volume to be replaced was prescribed according to a standard formula as per asfa guidelines. In most studies, volume of replacement solutions were about two times the plasma volume of the patients and average were 4 sessions. Taking into account the risks of blood component transfusion, and costs incurred crystalloids have become a major part of replacement fluids. In their study, 22% of plasma volume replacement was done using crystalloids with good clinical response. Conclusion: the complications noted in their study were trali in a myasthenic patient, hypotension possibly due to allergic reaction in a patient with vasculitis and cardiac arrest in a patient with mixed connective tissue disease following which the procedure was aborted. The authors concluded that the intolerance to tpe was minimal in their study. One likely reason could be the relatively lesser use of plasma in their patient population. Article citation: ranganathan l, menon r, ramakrishnan n, venkatraman r, ramachandran p. Therapeutic plasma exchange practices in intensive care unit. Indian j crit care med 2019;23(7):336? 338. Investigation is in process. A follow-up report will be provided.
Patient Sequence No: 1, Text Type: N, H10


[188575803] Per an article by ranaganathan et al, therapeutic plasma exchange practices in intensive care unit in the indian journal of critical care medicine, a retrospective analysis was done on patients who underwent therapeutic plasma exchange (tpe) procedures between may 2011 and august 2013. There were 56 patients in the study. Demographics were: males 33 (58. 93%) females 23 (41. 07%); age (mean? Std. Dev) 43. 08? 16. 84. Three patients in the study experienced reactions: transfusion associated acute lung injury (trali), hypotension, and cardiac arrest. The procedures were aborted following the reactions. Patient information and any treatment details for each of these patient reactions were not provided. Therefore, this report is being filed as a summary for the three patients. The disposable set is not available for return because it was discarded by the customer.
Patient Sequence No: 1, Text Type: D, B5


MAUDE Entry Details

Report Number1722028-2020-00125
MDR Report Key9860297
Report SourceFOREIGN,HEALTH PROFESSIONAL,L
Date Received2020-03-20
Date of Report2020-03-20
Date of Event2019-07-23
Date Mfgr Received2020-02-27
Date Added to Maude2020-03-20
Event Key0
Report Source CodeManufacturer report
Manufacturer LinkY
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag3
Reporter OccupationOTHER HEALTH CARE PROFESSIONAL
Health Professional3
Initial Report to FDA3
Report to FDA3
Event Location3
Manufacturer ContactSCOT HILDEN
Manufacturer Street10810 W. COLLINS AVE
Manufacturer CityLAKEWOOD CO 80215
Manufacturer CountryUS
Manufacturer Postal80215
Manufacturer Phone3032314970
Single Use3
Previous Use Code3
Event Type3
Type of Report3

Device Details

Brand NameSPECTRA OPTIA
Generic NameSPECTRA OPTIA EXCHANGE SET
Product CodeLKN
Date Received2020-03-20
Catalog Number10220
OperatorHEALTH PROFESSIONAL
Device AvailabilityN
Device Eval'ed by MfgrR
Device Sequence No1
Device Event Key0
ManufacturerTERUMO BCT
Manufacturer AddressLAKEWOOD CO 80215 US 80215


Patients

Patient NumberTreatmentOutcomeDate
101. Other 2020-03-20

© 2026 FDA.report
This site is not affiliated with or endorsed by the FDA.