UNK - NAIL HEAD ELEMENTS: FNS ANTIROTATION

MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed from a company representative,health report with the FDA on 2020-03-26 for UNK - NAIL HEAD ELEMENTS: FNS ANTIROTATION manufactured by Wrights Lane Synthes Usa Products Llc.

Event Text Entries

[186152273] This report is for an unknown nail head elements: fns anti-rotation/ unknown lot. Part and lot number are unknown; udi number is unknown. Complainant part is not expected to be returned for manufacturer review/ investigation. Without a lot number the device history records review could not be completed. Product was not returned. Based on the information available, it has been determined that no corrective and/or preventative action is proposed. This complaint will be accounted for and monitored via post market surveillance activities. If additional information is made available, the investigation will be updated as applicable. (b)(4). Device was used for treatment, not diagnosis. If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
Patient Sequence No: 1, Text Type: N, H10


[186152314] It was reported that on (b)(6) 2020 the patient underwent a revision of a femoral neck system (fns) implant that failed which resulted in a collapsed femoral head due to poor bone quality. None of the implants broke and there were no malfunctions of the device. It was revised to a bipolar hip. The procedure and patient status were unknown. This report is for one unknown nail head elements: fns anti-rotation. This is report 2 of 4 for (b)(4).
Patient Sequence No: 1, Text Type: D, B5


MAUDE Entry Details

Report Number2939274-2020-01542
MDR Report Key9883909
Report SourceCOMPANY REPRESENTATIVE,HEALTH
Date Received2020-03-26
Date of Report2020-02-28
Date Mfgr Received2020-02-28
Date Added to Maude2020-03-26
Event Key0
Report Source CodeManufacturer report
Manufacturer LinkY
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag3
Health Professional3
Initial Report to FDA3
Report to FDA3
Event Location3
Manufacturer ContactKARA DITTY-BOVARD
Manufacturer Street1302 WRIGHTS LANE EAST
Manufacturer CityWEST CHESTER PA 19380
Manufacturer CountryUS
Manufacturer Postal19380
Manufacturer Phone6103142063
Single Use3
Previous Use Code3
Event Type3
Type of Report3

Device Details

Brand NameUNK - NAIL HEAD ELEMENTS: FNS ANTIROTATION
Generic NameAPPLIANCE, FIXATION, NAIL
Product CodeKTT
Date Received2020-03-26
OperatorHEALTH PROFESSIONAL
Device AvailabilityN
Device Eval'ed by MfgrR
Device Sequence No1
Device Event Key0
ManufacturerWRIGHTS LANE SYNTHES USA PRODUCTS LLC
Manufacturer Address1302 WRIGHTS LANE EAST WEST CHESTER PA 19380 US 19380


Patients

Patient NumberTreatmentOutcomeDate
101. Required No Informationntervention 2020-03-26