BD VACUTAINER? SST? BLOOD COLLECTION TUBES 367988

MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed from a other,user facility report with the FDA on 2020-03-26 for BD VACUTAINER? SST? BLOOD COLLECTION TUBES 367988 manufactured by Becton, Dickinson & Co., (bd).

Event Text Entries

[188658247] A sample is available for evaluation. Upon completion of the investigation, a supplemental report will be filed.
Patient Sequence No: 1, Text Type: N, H10


[188658248] It was reported that erroneous results and hemolysis occurred with a bd vacutainer? Sst? Blood collection tubes. The following information was provided by the initial reporter: spoke with the customer and she states that the patient was initially drawn in the clinic and the phlebotomist assured her that she drew an sst tube and then the edta tube, and did not transfer any blood from the edta tube to the sst tube. The sample was slightly hemolyzed, and all the values were low. The patient was redrawn in the er and the sst results were all normal, and they also ran a na on the edta tube, which was also normal. Additionally, on 2020-03-09 the customer provided the following additional information: the specimen was drawn in an sst on (b)(6) 2020 at 1115, left to clot for 30 minutes, then spun at 3305 rpm for 10 minutes. Sample showed slight hemolysis and spun again for another 10 minutes. Sample was refrigerated before and during transportation. Sample was run and reported out at 1809 on (b)(6) 2020. The sample shows slight hemolysis. ), what instrument was used? (ortho vitros 5600), initial result drawn at 1115 (b)(6) 2020, repeated result from er drawn at 1930 (b)(6) 2020, reference range. Sodium: 114 critical, 138, 137-145 mmol/l. Potassium: 3. 7, 3. 8, 3. 5-5. 1 mmol/l. Chloride: 85, 100, 98-107 mmol/l. Co2: 16. 5, 25. 3 22. 0-30. 0 mmol/l. Glucose : 71, 94, 70-110 mg/dl. Bun: 14. 6, 21. 2, 7. 0-20. 0 mg/dl. Creatinine: 0. 5, 0. 7, 0. 7-1. 5 mg/dl. Calcium: 8. 3, 10. 2, 8. 4-10. 6 mg/dl. Bili total: 0. 5, 0. 5, 0. 2-1. 3 mg/dl. Alk phos: 46, 65, 36-126 unit/l. Ast: 31, 25, 15-46 unit/l. Alt: 15, 29, 13-69 unit/l. Total prot: 6. 4, 8. 4, 6. 3-8. 2 g/dl. Albumin: 3. 6, 4. 8, 3. 5-5. 0 g/dl. Globulin: 2. 8, 3. 6, 2. 5-3. 6 g/dl. Pt drawn and results came back as critically low for sodium and low for chloride and calcium. When the pt was redrawn and sample run in er, results came back positive. Initial draw done at clinic and second draw was done at the facility. All testing was performed at the same site at the mc. Pt was a difficult draw. Customer could not provide the lot as it was covered with a facility label.
Patient Sequence No: 1, Text Type: D, B5


MAUDE Entry Details

Report Number1024879-2020-00225
MDR Report Key9884503
Report SourceOTHER,USER FACILITY
Date Received2020-03-26
Date of Report2020-03-09
Date of Event2020-03-03
Date Mfgr Received2020-03-06
Device Manufacturer Date2019-09-11
Date Added to Maude2020-03-26
Event Key0
Report Source CodeManufacturer report
Manufacturer LinkY
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag3
Reporter OccupationOTHER HEALTH CARE PROFESSIONAL
Health Professional3
Initial Report to FDA3
Report to FDA3
Event Location3
Manufacturer ContactBDX BRETT WILKO
Manufacturer Street9450 SOUTH STATE STREET
Manufacturer CitySANDY UT 84070
Manufacturer CountryUS
Manufacturer Postal84070
Manufacturer Phone8015652341
Manufacturer G1BECTON, DICKINSON & CO., (BD)
Manufacturer Street1575 AIRPORT ROAD
Manufacturer CitySUMTER SC 29153
Manufacturer CountryUS
Manufacturer Postal Code29153
Single Use3
Previous Use Code3
Event Type3
Type of Report3

Device Details

Brand NameBD VACUTAINER? SST? BLOOD COLLECTION TUBES
Generic NameBLOOD SPECIMEN COLLECTION DEVICE
Product CodeJKA
Date Received2020-03-26
Returned To Mfg2020-03-12
Model Number367988
Catalog Number367988
Lot Number9254091
Device AvailabilityR
Device Eval'ed by MfgrN
Device Sequence No1
Device Event Key0
ManufacturerBECTON, DICKINSON & CO., (BD)
Manufacturer Address1575 AIRPORT ROAD SUMTER SC 29153 US 29153


Patients

Patient NumberTreatmentOutcomeDate
101. Other 2020-03-26