JP 1000ML EPUMP SET 973656

MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed from a company representative,foreig report with the FDA on 2020-03-31 for JP 1000ML EPUMP SET 973656 manufactured by Covidien.

Event Text Entries

[185813609] A device history record review could not be reviewed since the lot number is unknown. One used sample was received for evaluation. During the functional evaluation there was no food clogging the line however the silicone tubing was clearly damaged causing it to leak onto the union between the mistic and silicone tubing. Root cause could be found related to manufacturing/production process. The probable root cause may occur during use of the product due to stretching of the silicone tubing causing the detachment. A formal investigation action is not being taken since the reported condition is a rare occurrence. This complaint will be closed with no further action and will be used for tracking and trending purposes to determine a need for corrective/preventative actions.
Patient Sequence No: 1, Text Type: N, H10


[185813610] The customer reported that a leakage occurred from the pump set during priming.
Patient Sequence No: 1, Text Type: D, B5


MAUDE Entry Details

Report Number1282497-2020-08990
MDR Report Key9903390
Report SourceCOMPANY REPRESENTATIVE,FOREIG
Date Received2020-03-31
Date of Report2020-03-31
Date of Event2019-12-24
Date Mfgr Received2019-12-24
Date Added to Maude2020-03-31
Event Key0
Report Source CodeManufacturer report
Manufacturer LinkY
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag3
Health Professional3
Initial Report to FDA3
Report to FDA3
Event Location3
Manufacturer ContactJILL SARAIVA
Manufacturer Street15 HAMPSHIRE STREET
Manufacturer CityMANSFIELD MA 02048
Manufacturer CountryUS
Manufacturer Postal02048
Manufacturer Phone5086183640
Manufacturer G1COVIDIEN
Manufacturer Street15 HAMPSHIRE STREET
Manufacturer CityMANSFIELD MA 02048
Manufacturer CountryUS
Manufacturer Postal Code02048
Single Use3
Previous Use Code3
Event Type3
Type of Report3

Device Details

Brand NameJP 1000ML EPUMP SET
Generic NamePUMP, INFUSION, ENTERAL
Product CodeLZH
Date Received2020-03-31
Model Number973656
Catalog Number973656
Device AvailabilityY
Device Eval'ed by MfgrR
Device Sequence No1
Device Event Key0
ManufacturerCOVIDIEN