EVOS SMALL 2.5MM DRILL W/AO QC LONG 71175022

MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed from a company representative,health report with the FDA on 2020-03-31 for EVOS SMALL 2.5MM DRILL W/AO QC LONG 71175022 manufactured by Smith & Nephew, Inc..

Event Text Entries

[187076175] It was reported that during the procedure the fracture was reduced and bone void filler was used to fill the defect in the proximal tibia. Several k-wires were used to hold the fracture together and then a lateral proximal tibia plate was applied using more k-wires to hold it in place. Then two screws were placed into the plate. At that point the 2. 5mm drill was used again to prepare for another screw. While drilling the drill bit encountered a couple of the k-wires (? Pin traffic? ) while trying to get the perfect trajectory for the next screw. At that point the tip of the drill bit broke off inside the proximal tibia. Several attempts were made with multiple different instruments to try and recover the broken drill bit tip. Eventually it was determined by the surgeons that more harm would be caused to the patient by trying to retrieve the drill bit tip than leaving it in the patients tibia. Many x-rays were taken to confirm that the drill bit tip was not in the knee joint space and to confirm that it would not cause any harm to the patient. The case was completed with an approximate 5-minute delay.
Patient Sequence No: 1, Text Type: D, B5


MAUDE Entry Details

Report Number1020279-2020-01103
MDR Report Key9903428
Report SourceCOMPANY REPRESENTATIVE,HEALTH
Date Received2020-03-31
Date of Report2020-03-31
Date of Event1901-01-01
Date Mfgr Received2020-03-05
Date Added to Maude2020-03-31
Event Key0
Report Source CodeManufacturer report
Manufacturer LinkY
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag3
Health Professional0
Initial Report to FDA0
Report to FDA3
Event Location3
Manufacturer ContactDR. SARAH FREESTONE
Manufacturer Street1450 BROOKS ROAD
Manufacturer CityMEMPHIS TN 38116
Manufacturer CountryUS
Manufacturer Postal38116
Manufacturer Phone0447940038
Manufacturer G1SMITH & NEPHEW, INC.
Manufacturer Street1450 BROOKS ROAD
Manufacturer CityMEMPHIS TN 38116
Manufacturer CountryUS
Manufacturer Postal Code38116
Single Use3
Previous Use Code3
Event Type3
Type of Report3

Device Details

Brand NameEVOS SMALL 2.5MM DRILL W/AO QC LONG
Generic NameINSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWRED MOTOR AND ACCESSORY/ATTACHMNT
Product CodeHWE
Date Received2020-03-31
Model Number71175022
Catalog Number71175022
Lot NumberUNKNOWN/UNREADABLE
OperatorHEALTH PROFESSIONAL
Device Availability*
Device Eval'ed by MfgrR
Device Sequence No1
Device Event Key0
ManufacturerSMITH & NEPHEW, INC.
Manufacturer Address1450 BROOKS ROAD MEMPHIS TN 38116 US 38116