HILL-ROM VERSACARE PATIENT HELPER ADAPTER * 00-0965-000-00

MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed with the FDA on 2008-01-25 for HILL-ROM VERSACARE PATIENT HELPER ADAPTER * 00-0965-000-00 manufactured by Zimmer , Inc..

Event Text Entries

[787906] Hospital purchased hill-rom versa care beds for use on a newly opening trauma specialty care unit. We had a need for traction patient assist brackets for the new beds. ( hill-rom publishes a document of traction accessories available from other vendors for the versa care bed on their website @ hill-rom. Com ) we purchased the zimmer patient helper bracket/bar assembly only to find out once they were installed on the beds that there is an inherent safety problem with the bracket set up. This helper bar slides into a tube attached to the head of the bed and is secured by a hand knob at an adjustment clamp, allowing you to vary the height of the bar assembly above the patient. If you attempt to adjust the bar by loosening the hand clamp, and you are not holding onto the bar, it will slam down towards the patient's head. There is a potential for serious injury. The other problem identified; as the bar slams down, the metal on the bar gets shaved, if you will , to a point of having very sharp burrs left on the bar. Those burrs could cause cuts to caregivers hands or anyone who tries to get the bar off the bed. ====================== manufacturer response for traction patient assist bar, hill-rom versacare patient helper adapter======================initially they indicated there was no type of saftey lock or stop available and that when we adjusted the bar we had to hold on to it. Today we had a rep from zimmer come in to see our concern first hand, we gave him a little demo of the slaming down of the bar on an empty bed, and showed him the shaved metal burrs on the bar afterwards.
Patient Sequence No: 1, Text Type: D, B5


MAUDE Entry Details

Report Number997626
MDR Report Key997626
Date Received2008-01-25
Date of Report2008-01-25
Date of Event2008-01-07
Report Date2008-01-25
Date Reported to FDA2008-01-25
Date Added to Maude2008-02-14
Event Key0
Report Source CodeUser Facility report
Manufacturer LinkN
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag0
Health Professional3
Initial Report to FDA3
Report to FDA3
Event Location3
Single Use0
Previous Use Code0
Event Type3
Type of Report3

Device Sequence Number: 1

Brand NameHILL-ROM VERSACARE PATIENT HELPER ADAPTER
Generic NameTRACTION ASSIST SYSTEM
Product CodeILZ
Date Received2008-01-25
Model Number*
Catalog Number00-0965-000-00
Lot Number*
ID Number*
OperatorOTHER
Device AvailabilityY
Device Age1 DY
Implant FlagN
Date Removed*
Device Sequence No1
Device Event Key966490
ManufacturerZIMMER , INC.
Manufacturer Address345 EAST MAIN STREET WARSAW IN 46580 US

Device Sequence Number: 2

Brand NameVERSA CARE BED
Generic NameBED, HOSPITAL
Product CodeFNL
Date Received2008-01-25
Model Number*
Catalog Number*
Lot Number*
ID Number*
Device Age1 DY
Implant FlagN
Date Removed*
Device Sequence No2
Device Event Key966491
ManufacturerHILL-ROM COMPANY, INC.
Manufacturer Address1069 STATE ROAD 46 EAST; MAIL BATESVILLE IN 470069167 US


Patients

Patient NumberTreatmentOutcomeDate
10 2008-01-25

© 2026 FDA.report
This site is not affiliated with or endorsed by the FDA.