Endoscopic Access Overtube, Gastroenterology-urology

Device Code: 1782

Product Code(s): FED

Definition: To Facilitate Passage And Aid Advancement Of Endoscopes Into The Body, Especially In Cases Of Repeated Intubation.

Device Classification Information

Device Type ID1782
Device NameEndoscopic Access Overtube, Gastroenterology-urology
Physical StateOvertube
Technical MethodEndoscope Inserted And Advanced Through Center Of Device
Target AreaVarious Openings In Gi And Gu Tract
Regulation DescriptionEndoscope And Accessories.
Regulation Medical SpecialtyGastroenterology/Urology
Review PanelGastroenterology/Urology
Premarket Review Office Of Device Evaluation (ODE)
Division Of Reproductive, Gastro-Renal, And Urological Devices (DRGUD)
Urology And Lithotripsy Devices Branch (ULDB)
Submission Type510(k)
CFR Regulation Number876.1500 [🔎]
FDA Device ClassificationClass 2 Medical Device
Product CodeFED
GMP ExemptNo
Summary MREligible
Implanted DeviceNo
Life Support DeviceNo
Third Party Review Eligible For Accredited Persons Program

Recognized Standards

Total Product Life Cycle

Device Type ID1782
DeviceEndoscopic Access Overtube, Gastroenterology-urology
Product CodeFED
FDA Device ClassificationClass 2 Medical Device
Regulation DescriptionEndoscope And Accessories.
CFR Regulation Number876.1500 [🔎]
Premarket Reviews
ManufacturerDecision
BODDINGTONS PLASTICS LTD
 
SUBSTANTIALLY EQUIVALENT
2
BOSTON SCIENTIFIC
 
SUBSTANTIALLY EQUIVALENT
2
BOSTON SCIENTIFIC CORP.
 
SUBSTANTIALLY EQUIVALENT
2
C.R. BARD, INC.
 
SUBSTANTIALLY EQUIVALENT
1
C2 THERAPEUTICS
 
SUBSTANTIALLY EQUIVALENT
1
COLOPLAST MANUFACTURING US LLC
 
SUBSTANTIALLY EQUIVALENT
2
COOK, INC.
 
SUBSTANTIALLY EQUIVALENT
1
ENDO-AID, INC.
 
SUBSTANTIALLY EQUIVALENT
1
MEDIVATORS REPROCESSING SYSTEMS
 
SUBSTANTIALLY EQUIVALENT
1
MEDIVATORS, INC.
 
SUBSTANTIALLY EQUIVALENT
1
MICRO-TECH (NAN JING) CO., LTD.
 
SUBSTANTIALLY EQUIVALENT
1
STERIS CORPORATION
 
SUBSTANTIALLY EQUIVALENT
1
VISIONSENSE LTD.
 
SUBSTANTIALLY EQUIVALENT
1
WELL LEAD MEDICAL CO. LTD
 
SUBSTANTIALLY EQUIVALENT
1
Device Problems
Shaft
25
Adverse Event Without Identified Device Or Use Problem
12
Torn Material
12
Appropriate Term/Code Not Available
10
Break
9
Peeled / Delaminated
9
Fracture
5
Device Contamination With Chemical Or Other Material
4
Detachment Of Device Component
4
Insufficient Information
4
Material Perforation
3
Partial Blockage
3
Tip
3
Delamination
2
Patient-Device Incompatibility
2
Flaked
2
Difficult To Advance
1
Microbial Contamination Of Device
1
Detachment Of Device Or Device Component
1
Device Contaminated During Manufacture Or Shipping
1
Material Separation
1
Device Packaging Compromised
1
Device Handling Problem
1
Inflation Problem
1
Difficult To Remove
1
Wrinkled
1
Improper Or Incorrect Procedure Or Method
1
Failure To Advance
1
Material Integrity Problem
1
Deflation Problem
1
Retraction Problem
1
Structural Problem
1