IEC 60601-2-1 Edition 3.1 2014-07 Medical electrical equipment - Part 2-1: Particular requirements for the basic safety and essential performance of electron accelerators in the range 1 MeV to 50 MeV |
Recognition Date | 2015-01-27 |
Recognition List | 038 |
Recognition Number | 12-285 |
Extent | Complete standard |
Standards Orgs | IEC International Electrotechnical Commission http://www.iec.ch/ |
STG | Radiology |
FDA Tech | John Chen FDA/OMPT/CDRH/OIR/DRH/NMRT/ 301-796-6540 john.chen@fda.hhs.gov |
.stds { color: #000000; float: center; width: 950px; margin: 0px 25px 0px 0px; } .stds-middle { color: #000000; float: center; width: 575px; margin: 0px 50px 50px 50px; } /* .stds-left { float: left; margin: 9px 30px 0px 0; } */ .stds-left { color: #000000; float: left; width: 700px; margin: 9px 0px 0px 0px; } .stds-search-left { float: left; width: 610px; margin: 9px 30px 0px 0; } .stds-search-right { float: right; width: 190px; margin: 9px 18px 0 0; padding: 8px 12px 10px 12px; background-color: #f9f9f3; border: 1px solid #b0b0b0; -webkit-border-radius: 6px; -moz-border-radius: 6px; border-radius: 6px; } .stds-right { color: #000000; float: right; width: 170px; margin: 9px 18px 0 0; padding: 8px 12px 10px 12px; background-color: #f3f3f3; border: 1px solid #b0b0b0; border-radius: 6px; } .stds-intro { margin: 0px 0px 18px 0px; padding: 5px 12px 12px 12px; background-color: #e8eff5; border: 1px solid #b0b0b0; border-radius: 6px; } #stds_nr-form { margin-top: 18px; padding-top: 12px; border-top: 1px dashed #b0b0b0; } #stds-form { table-layout:fixed; width: 700px; font-size: 11px; border: 1px solid #b0b0b0; background-color: #f9f9f3; } #stds-form-title{ padding: 3px 3px 3px 3px; width: 100%; background-color: #e8eff5; border-bottom: 1px solid #b0b0b0; margin-top: 0px; } #stds-form-title-left { font-size: 13px; font-weight:normal; } #stds-form-title-right { /*float: right;*/ font-size: 11px; padding: 0px 0px 0px 500px; } #stds-form-results-right { /*float: right;*/ font-size: 11px; padding: 0px 0px 0px 600px; } #stds-search { height: 18px; margin: 0px; padding: 3px 10px; border: 1px solid #b0b0b0; font-size: 12px; color: #484138; } #stds-search:focus, #stds-search:hover { -webkit-box-shadow: 0 0px 6px rgba(0,0,0,.1); -moz-box-shadow: 0 0px 6px rgba(0,0,0,.1); box-shadow: 0 0px 6px rgba(0,0,0,.1); } #stds-results-number { margin-bottom: 12px; font-size: 10px; font-weight: bold; } #stds-results-table { margin-left:auto; margin-right:auto; text-align:left; padding: 0; border-collapse:collapse; table-layout:fixed; background-color: #f9f9f3; border-color: #b0b0b0; border-width: 0 0 1px 1px; border-style: solid; } #stds-results-table th { padding: 6px 12px; background-color: #f9f9f3; border-color: #b0b0b0; border-width: 1px 1px 0 0; border-style: solid; font-size: 12px; } #stds-results-table td { padding: 6px 12px; border-color: #b0b0b0; border-width: 1px 1px 0 0; border-style: solid; text-transform: capitalize; } #stds-results-table tr:nth-child(odd) { /* background-color: #f3f3f3; */ } .sort { float: right; margin: 0px 10px 0px 0px; padding: 0px 5px 5px 5px; } /* .sort { float: right; margin-top: 5px;} */ .sort a { color: #484138; } .sort a:hover { color: #0f2a8c; } Recognized Consensus Standards // Quick Links: Skip to main page content Skip to Search Skip to Topics Menu Skip to Common Links U.S. Food & Drug Administration Follow FDA En Español Search FDA Home Food Drugs Medical Devices Radiation-Emitting Products Vaccines, Blood & Biologics Animal & Veterinary Cosmetics Tobacco Products Recognized Consensus Standards var MP = { Version: '1.0.22', Domains: {'es':'esp.fda.gov'}, SrcLang: 'en', UrlLang: 'mp_js_current_lang', SrcUrl: unescape('mp_js_orgin_url'), init: function(){ if (MP.UrlLang.indexOf('p_js_')==1) { MP.SrcUrl=window.top.document.location.href; MP.UrlLang=MP.SrcLang; } }, getCookie: function(name){ var start=document.cookie.indexOf(name+'='); if(start < 0) return null; start=start+name.length+1; var end=document.cookie.indexOf(';', start); if(end < 0) end=document.cookie.length; while (document.cookie.charAt(start)==' '){ start++; } return unescape(document.cookie.substring(start,end)); }, setCookie: function(name,value,path,domain){ var cookie=name+'='+escape(value); if(path)cookie+='; path='+path; if(domain)cookie+='; domain='+domain; var now=new Date(); now.setTime(now.getTime()+1000*60*60*24*365); cookie+='; expires='+now.toUTCString(); document.cookie=cookie; }, switchLanguage: function(lang){ if(lang!=MP.SrcLang){ var script=document.createElement('SCRIPT'); script.src=location.protocol+'//'+MP.Domains[lang]+'/'+MP.SrcLang+lang+'/?1023749632;'+encodeURIComponent(MP.SrcUrl); document.body.appendChild(script); } else if(lang==MP.SrcLang && MP.UrlLang!=MP.SrcLang){ var script=document.createElement('SCRIPT'); script.src=location.protocol+'//'+MP.Domains[MP.UrlLang]+'/'+MP.SrcLang+MP.UrlLang+'/?1023749634;'+encodeURIComponent(location.href); document.body.appendChild(script); } return false; }, switchToLang: function(url) { window.top.location.href=url; } }; var addthis_config = {data_track_clickback: true, ui_508_compliant: true, services_compact: 'facebook, twitter, linkedin, pinterest_share, email', services_exclude: 'print', image_container: "#user_provided" } ; FDA Home Medical Devices Databases -
IEC 60601-2-1:2009 applies to the basic safety and essential performance of electron accelerators in the range 1 MeV to 50 MeV, used for treatment of patients. This particular standard establishes requirements to be complied with by manufacturers in the design and construction of electron accelerators for use in radiotherapy; it does not attempt to define their optimum performance requirements. Its purpose is to identify those features of design that are regarded, at the present time, as essential for the safe operation of such medical electrical equipment. It places limits on the degradation of medical electrical equipment performance beyond which it can be presumed that a fault condition exists and where an interlock then operates to prevent continued operation of the me equipment. This third edition cancels and replaces the second edition published in 1998 and its Amendment 1 (2002). It constitutes a technical revision. This third edition addresses the following issues not covered in previous editions:
- alignment with the new relevant collateral standards;
- new technologies in radiotherapy, including stereotactic radiosurgery (SRS) and stereotactic radiotherapy (SRT), intensity modulated radiotherapy (IMRT), electronic imaging devices (e.g. EPID) and moving beam radiotherapy (dynamic therapy).
Regulation Number | Device Name | Device Class | Product Code |
§892.5050 | Accelerator, Linear, Medical | Class 2 | IYE |
§892.5050 | Accessory - Film Dosimetry System | Class 2 | MWW |
§892.5050 | Betatron, Medical | Class 2 | IYG |
§892.5050 | Cyclotron, Medical | Class 2 | IWK |
§892.5050 | Dosimeter, Ionizing Radiation, Implanted | Class 2 | NZT |
§892.5050 | Microtron, Medical | Class 2 | JAE |
§892.5050 | Synchrotron, Medical | Class 2 | IWM |
§892.5050 | System, Planning, Radiation Therapy Treatment | Class 2 | MUJ |
§892.5050 | System, Radiation Therapy, Charged-Particle, Medical | Class 2 | LHN |