ISO 13959 Third edition 2014-04-01 Water for haemodialysis and related therapies |
Recognition Date | 2015-08-14 |
Recognition List | 040 |
Recognition Number | 9-98 |
Extent | Complete standard |
Standards Orgs | ISO International Organization for Standardization https://www.iso.org/ |
STG | ObGyn/Gastroenterology/Urology |
FDA Tech | .stds { color: #000000; float: center; width: 950px; margin: 0px 25px 0px 0px; } .stds-middle { color: #000000; float: center; width: 575px; margin: 0px 50px 50px 50px; } /* .stds-left { float: left; margin: 9px 30px 0px 0; } */ .stds-left { color: #000000; float: left; width: 700px; margin: 9px 0px 0px 0px; } .stds-search-left { float: left; width: 610px; margin: 9px 30px 0px 0; } .stds-search-right { float: right; width: 190px; margin: 9px 18px 0 0; padding: 8px 12px 10px 12px; background-color: #f9f9f3; border: 1px solid #b0b0b0; -webkit-border-radius: 6px; -moz-border-radius: 6px; border-radius: 6px; } .stds-right { color: #000000; float: right; width: 170px; margin: 9px 18px 0 0; padding: 8px 12px 10px 12px; background-color: #f3f3f3; border: 1px solid #b0b0b0; border-radius: 6px; } .stds-intro { margin: 0px 0px 18px 0px; padding: 5px 12px 12px 12px; background-color: #e8eff5; border: 1px solid #b0b0b0; border-radius: 6px; } #stds_nr-form { margin-top: 18px; padding-top: 12px; border-top: 1px dashed #b0b0b0; } #stds-form { table-layout:fixed; width: 700px; font-size: 11px; border: 1px solid #b0b0b0; background-color: #f9f9f3; } #stds-form-title{ padding: 3px 3px 3px 3px; width: 100%; background-color: #e8eff5; border-bottom: 1px solid #b0b0b0; margin-top: 0px; } #stds-form-title-left { font-size: 13px; font-weight:normal; } #stds-form-title-right { /*float: right;*/ font-size: 11px; padding: 0px 0px 0px 500px; } #stds-form-results-right { /*float: right;*/ font-size: 11px; padding: 0px 0px 0px 600px; } #stds-search { height: 18px; margin: 0px; padding: 3px 10px; border: 1px solid #b0b0b0; font-size: 12px; color: #484138; } #stds-search:focus, #stds-search:hover { -webkit-box-shadow: 0 0px 6px rgba(0,0,0,.1); -moz-box-shadow: 0 0px 6px rgba(0,0,0,.1); box-shadow: 0 0px 6px rgba(0,0,0,.1); } #stds-results-number { margin-bottom: 12px; font-size: 10px; font-weight: bold; } #stds-results-table { margin-left:auto; margin-right:auto; text-align:left; padding: 0; border-collapse:collapse; table-layout:fixed; background-color: #f9f9f3; border-color: #b0b0b0; border-width: 0 0 1px 1px; border-style: solid; } #stds-results-table th { padding: 6px 12px; background-color: #f9f9f3; border-color: #b0b0b0; border-width: 1px 1px 0 0; border-style: solid; font-size: 12px; } #stds-results-table td { padding: 6px 12px; border-color: #b0b0b0; border-width: 1px 1px 0 0; border-style: solid; text-transform: capitalize; } #stds-results-table tr:nth-child(odd) { /* background-color: #f3f3f3; */ } .sort { float: right; margin: 0px 10px 0px 0px; padding: 0px 5px 5px 5px; } /* .sort { float: right; margin-top: 5px;} */ .sort a { color: #484138; } .sort a:hover { color: #0f2a8c; } Recognized Consensus Standards // Quick Links: Skip to main page content Skip to Search Skip to Topics Menu Skip to Common Links U.S. Food & Drug Administration Follow FDA En Español Search FDA Home Food Drugs Medical Devices Radiation-Emitting Products Vaccines, Blood & Biologics Animal & Veterinary Cosmetics Tobacco Products Recognized Consensus Standards var MP = { Version: '1.0.22', Domains: {'es':'esp.fda.gov'}, SrcLang: 'en', UrlLang: 'mp_js_current_lang', SrcUrl: unescape('mp_js_orgin_url'), init: function(){ if (MP.UrlLang.indexOf('p_js_')==1) { MP.SrcUrl=window.top.document.location.href; MP.UrlLang=MP.SrcLang; } }, getCookie: function(name){ var start=document.cookie.indexOf(name+'='); if(start < 0) return null; start=start+name.length+1; var end=document.cookie.indexOf(';', start); if(end < 0) end=document.cookie.length; while (document.cookie.charAt(start)==' '){ start++; } return unescape(document.cookie.substring(start,end)); }, setCookie: function(name,value,path,domain){ var cookie=name+'='+escape(value); if(path)cookie+='; path='+path; if(domain)cookie+='; domain='+domain; var now=new Date(); now.setTime(now.getTime()+1000*60*60*24*365); cookie+='; expires='+now.toUTCString(); document.cookie=cookie; }, switchLanguage: function(lang){ if(lang!=MP.SrcLang){ var script=document.createElement('SCRIPT'); script.src=location.protocol+'//'+MP.Domains[lang]+'/'+MP.SrcLang+lang+'/?1023749632;'+encodeURIComponent(MP.SrcUrl); document.body.appendChild(script); } else if(lang==MP.SrcLang && MP.UrlLang!=MP.SrcLang){ var script=document.createElement('SCRIPT'); script.src=location.protocol+'//'+MP.Domains[MP.UrlLang]+'/'+MP.SrcLang+MP.UrlLang+'/?1023749634;'+encodeURIComponent(location.href); document.body.appendChild(script); } return false; }, switchToLang: function(url) { window.top.location.href=url; } }; var addthis_config = {data_track_clickback: true, ui_508_compliant: true, services_compact: 'facebook, twitter, linkedin, pinterest_share, email', services_exclude: 'print', image_container: "#user_provided" } ; FDA Home Medical Devices Databases - |
.stds { color: #000000; float: center; width: 950px; margin: 0px 25px 0px 0px; } .stds-middle { color: #000000; float: center; width: 575px; margin: 0px 50px 50px 50px; } /* .stds-left { float: left; margin: 9px 30px 0px 0; } */ .stds-left { color: #000000; float: left; width: 700px; margin: 9px 0px 0px 0px; } .stds-search-left { float: left; width: 610px; margin: 9px 30px 0px 0; } .stds-search-right { float: right; width: 190px; margin: 9px 18px 0 0; padding: 8px 12px 10px 12px; background-color: #f9f9f3; border: 1px solid #b0b0b0; -webkit-border-radius: 6px; -moz-border-radius: 6px; border-radius: 6px; } .stds-right { color: #000000; float: right; width: 170px; margin: 9px 18px 0 0; padding: 8px 12px 10px 12px; background-color: #f3f3f3; border: 1px solid #b0b0b0; border-radius: 6px; } .stds-intro { margin: 0px 0px 18px 0px; padding: 5px 12px 12px 12px; background-color: #e8eff5; border: 1px solid #b0b0b0; border-radius: 6px; } #stds_nr-form { margin-top: 18px; padding-top: 12px; border-top: 1px dashed #b0b0b0; } #stds-form { table-layout:fixed; width: 700px; font-size: 11px; border: 1px solid #b0b0b0; background-color: #f9f9f3; } #stds-form-title{ padding: 3px 3px 3px 3px; width: 100%; background-color: #e8eff5; border-bottom: 1px solid #b0b0b0; margin-top: 0px; } #stds-form-title-left { font-size: 13px; font-weight:normal; } #stds-form-title-right { /*float: right;*/ font-size: 11px; padding: 0px 0px 0px 500px; } #stds-form-results-right { /*float: right;*/ font-size: 11px; padding: 0px 0px 0px 600px; } #stds-search { height: 18px; margin: 0px; padding: 3px 10px; border: 1px solid #b0b0b0; font-size: 12px; color: #484138; } #stds-search:focus, #stds-search:hover { -webkit-box-shadow: 0 0px 6px rgba(0,0,0,.1); -moz-box-shadow: 0 0px 6px rgba(0,0,0,.1); box-shadow: 0 0px 6px rgba(0,0,0,.1); } #stds-results-number { margin-bottom: 12px; font-size: 10px; font-weight: bold; } #stds-results-table { margin-left:auto; margin-right:auto; text-align:left; padding: 0; border-collapse:collapse; table-layout:fixed; background-color: #f9f9f3; border-color: #b0b0b0; border-width: 0 0 1px 1px; border-style: solid; } #stds-results-table th { padding: 6px 12px; background-color: #f9f9f3; border-color: #b0b0b0; border-width: 1px 1px 0 0; border-style: solid; font-size: 12px; } #stds-results-table td { padding: 6px 12px; border-color: #b0b0b0; border-width: 1px 1px 0 0; border-style: solid; text-transform: capitalize; } #stds-results-table tr:nth-child(odd) { /* background-color: #f3f3f3; */ } .sort { float: right; margin: 0px 10px 0px 0px; padding: 0px 5px 5px 5px; } /* .sort { float: right; margin-top: 5px;} */ .sort a { color: #484138; } .sort a:hover { color: #0f2a8c; } Recognized Consensus Standards // Quick Links: Skip to main page content Skip to Search Skip to Topics Menu Skip to Common Links U.S. Food & Drug Administration Follow FDA En Español Search FDA Home Food Drugs Medical Devices Radiation-Emitting Products Vaccines, Blood & Biologics Animal & Veterinary Cosmetics Tobacco Products Recognized Consensus Standards var MP = { Version: '1.0.22', Domains: {'es':'esp.fda.gov'}, SrcLang: 'en', UrlLang: 'mp_js_current_lang', SrcUrl: unescape('mp_js_orgin_url'), init: function(){ if (MP.UrlLang.indexOf('p_js_')==1) { MP.SrcUrl=window.top.document.location.href; MP.UrlLang=MP.SrcLang; } }, getCookie: function(name){ var start=document.cookie.indexOf(name+'='); if(start < 0) return null; start=start+name.length+1; var end=document.cookie.indexOf(';', start); if(end < 0) end=document.cookie.length; while (document.cookie.charAt(start)==' '){ start++; } return unescape(document.cookie.substring(start,end)); }, setCookie: function(name,value,path,domain){ var cookie=name+'='+escape(value); if(path)cookie+='; path='+path; if(domain)cookie+='; domain='+domain; var now=new Date(); now.setTime(now.getTime()+1000*60*60*24*365); cookie+='; expires='+now.toUTCString(); document.cookie=cookie; }, switchLanguage: function(lang){ if(lang!=MP.SrcLang){ var script=document.createElement('SCRIPT'); script.src=location.protocol+'//'+MP.Domains[lang]+'/'+MP.SrcLang+lang+'/?1023749632;'+encodeURIComponent(MP.SrcUrl); document.body.appendChild(script); } else if(lang==MP.SrcLang && MP.UrlLang!=MP.SrcLang){ var script=document.createElement('SCRIPT'); script.src=location.protocol+'//'+MP.Domains[MP.UrlLang]+'/'+MP.SrcLang+MP.UrlLang+'/?1023749634;'+encodeURIComponent(location.href); document.body.appendChild(script); } return false; }, switchToLang: function(url) { window.top.location.href=url; } }; var addthis_config = {data_track_clickback: true, ui_508_compliant: true, services_compact: 'facebook, twitter, linkedin, pinterest_share, email', services_exclude: 'print', image_container: "#user_provided" } ; FDA Home Medical Devices Databases -
ISO 13959:2014 specifies minimum requirements for water to be used in haemodialysis and related therapies.
ISO 13959:2014 includes water to be used in the preparation of concentrates, dialysis fluids for haemodialysis, haemodiafiltration and haemofiltration, and for the reprocessing of Haemodialysers.
Regulation Number | Device Name | Device Class | Product Code |
§876.5860 | Disinfectant, Dialysate Delivery System | Class 2 | NII |
§876.5860 | System, Dialysate Delivery, Sealed | Class 2 | FII |
§876.5820 | Dialysate Concentrate For Hemodialysis (Liquid Or Powder) | Class 2 | KPO |
§876.5820 | Meter, Conductivity, Induction, Remote Type | Class 2 | FLB |
§876.5820 | Set, Dialysis, Single Needle With Uni-Directional Pump | Class 2 | FIF |
§876.5820 | Set, Dialysis, Single Needle With Uni-Directional Pump, Reprocessed | Class 2 | NNG |
§876.5820 | Solution-Test Standard-Conductivity, Dialysis | Class 2 | FKH |
§876.5820 | Strip, Dialysate Ph Indicator | Class 2 | MNV |
§876.5820 | Strip, Dialysate, Ph, Bicarbonate, Glucose, Acid, Indicator | Class 2 | NTZ |
§876.5820 | Subsystem, Proportioning | Class 2 | FKR |
§876.5820 | System, Dialysate Delivery, Central Multiple Patient | Class 2 | FKQ |
§876.5820 | System, Dialysate Delivery, Recirculating | Class 2 | FIK |
§876.5820 | System, Dialysate Delivery, Recirculating, Single Pass | Class 2 | FIJ |
§876.5820 | System, Dialysate Delivery, Single Pass | Class 2 | FIL |
§876.5820 | System, Dialysate Delivery, Single Patient | Class 2 | FKP |
§876.5665 | Disinfectant, Subsystem, Water Purification | Class 2 | NIH |
§876.5665 | Subsystem, Water Purification | Class 2 | FIP |
§876.5665 | System, Water Purification, General Medical Use | Class 2 | NHV |
Guidance for the Content of Premarket Notifications for Water Purification Components and Systems for Hemodialysis, Issued May 1997. Regulatory Status of Disinfectants Used to Process Dialysate Delivery Systems and Water Purification Systems for Hemodialysis; Guidance for Industry and FDA, Issued August 2002. |