6 GUDID devices
An assembly of sterile devices designed to create an opening between a blood vessel and a vascular graft (native or synthetic) during a vascular surgical procedure [e.g., coronary artery bypass grafting (CABG), or arteriovenous fistula (AVF) grafting]. It t...
187 GUDID devices
A sterile assembly of implantable devices designed for general orthopaedic repairs including procedures for long bone fractures, hips, spine, bone grafting and reinforcement of bone. It may also be used for supplementary fixation and reduction with bone pla...
72 GUDID devices
A non-sterile assembly of implantable devices designed for general orthopaedic repairs including procedures for long bone fractures, hips, spine, bone grafting and reinforcement of bone. It may also be used for supplementary fixation and reduction with bone...
30 GUDID devices
A dedicated battery-powered assembly of devices intended to be used to remove circular sections of the skull vault (calvarium) to provide access to the interior for diagnosis (e.g., the insertion of a neuroscope), or treatments [e.g., to alleviate intracran...
378 GUDID devices
An assembly of devices designed to resect bones, tough tissues (e.g., cartilage, ligaments), and soft tissues during a surgical procedure; it is not dedicated to a specific clinical application. It includes a mains electricity (AC-powered) control unit whic...
190 GUDID devices
A hand-held, pneumatically-powered component of a surgical power tool assembly designed to convert the energy from a compressed gas source [e.g., surgical-grade air or nitrogen (N2)] into a non-dedicated mechanical energy for drilling or sawing during denta...
151 GUDID devices
A hand-held, electrically-powered component of a dental power tool assembly designed to convert electrical energy into a non-dedicated mechanical energy for drilling or sawing during dental surgery. It is designed to accept handpiece components/attachments ...
67 GUDID devices
A hand-held, electrically-powered component of a surgical power tool assembly designed to convert electrical energy into a non-dedicated mechanical energy to perform a variety of non-dental surgical procedures such as drilling or sawing of bones and tough t...
60 GUDID devices
A small component of a powered reaming assembly intended to connect to a surgical power tool system motor [it is locked and held in a collet or quick coupling and not simply gripped in a drill chuck (Jacobs chuck)] to convert the non-dedicated mechanical en...
58 GUDID devices
An assembly of devices intended to be used in a dental laboratory to bore/cut/grind dental fixtures, appliances, and materials for their preparation or repair. It typically consists of a drilling handpiece, a compact mains electricity (AC-powered) motor, an...
54 GUDID devices
An assembly of devices designed to resect bones and tough tissues (e.g., cartilage, ligaments) during a surgical procedure; it is not dedicated to a specific clinical application. It includes a rechargeable battery pack/control unit which supplies low-volta...
53 GUDID devices
An assembly of devices designed to resect bones and tough tissues (e.g., cartilage, ligaments) during a surgical procedure; it is not dedicated to a specific clinical application. It includes a pneumatically-powered control unit which controls output of nit...
39 GUDID devices
A hand-held, electrically-powered component of a surgical power tool assembly designed to convert electrical energy into a non-dedicated mechanical energy to perform a variety of surgical procedures such as drilling or sawing of bones and tough tissues; it ...
8 GUDID devices
A hand-held, pneumatically-powered component of a surgical power tool assembly designed to convert the energy from a compressed gas source [e.g., surgical-grade air or nitrogen (N2)] into a non-dedicated mechanical energy to perform a variety of non-dental ...
8 GUDID devices
A hand-held, electrically-powered component of a surgical power tool assembly designed to convert electrical energy into a non-dedicated mechanical energy to perform a variety of non-dental surgical procedures such as drilling or sawing of bones and tough t...
1 GUDID devices
A dedicated surgical instrument intended to be used to temporarily secure sliding bearings on the rod of an implantable spinal spring-distraction system to ensure that the spring remains locked in a compressed state during implantation of the spinal assembl...
1 GUDID devices
A hand-held, pneumatically-powered component of a surgical power tool assembly designed to convert the energy from a compressed gas source [e.g., surgical-grade air or nitrogen (N2)] into a non-dedicated mechanical energy to perform a variety of non-dental ...
680 GUDID devices
A non-sterile, noninvasive tool designed to support assembly of the component parts of an orthopaedic implant or surgical instrument during an orthopaedic surgical procedure, typically when component sizes are determined during the procedure [e.g., stem, ne...
244 GUDID devices
A mobile assembly of mains electricity (AC-powered) devices intended to provide a physician with optical tools to track manual surgical instruments and locate target anatomical structures with respect to pre-acquired images (e.g., CT/MRI scan) or real-time ...
219 GUDID devices
An assembly of devices intended to provide a physician with an electromagnetic (EM) tool for image registration and/or tracking of manual surgical instruments with respect to pre-acquired images (e.g., CT/MRI scan) or real-time data [e.g., ultrasound (US)] ...
200 GUDID devices
An assembly of electrically-powered devices intended for the treatment and/or diagnosis of neurological, psychiatric and/or cognitive conditions (e.g., Alzheimer's disease, major depressive disorder, pain) through noninvasive magnetic stimulation of the bra...
174 GUDID devices
An assembly of devices intended to provide a physician with an electromagnetic (EM) tool for image registration and/or tracking of manual surgical instruments typically with respect to pre-acquired images (e.g., CT/MRI scan) or real-time data [e.g., ultraso...
121 GUDID devices
A mobile assembly of electrically-powered devices intended to provide a physician with optical tools to track manual surgical instruments and locate anatomical structures with respect to pre-acquired images (e.g., CT/MRI scan) or real-time data [e.g., endos...
116 GUDID devices
An assembly of devices designed to both bore/excavate and saw bones, teeth, and tough tissues during a dental/maxillofacial surgical procedure. It typically consists of a motorized drill handpiece and/or motor, a control unit, and a variety of attachments u...
82 GUDID devices
A non-sterile assembly of devices designed to provide the operator with a workstation for the preparation and pretensioning of a graft prior to implantation. It typically consists of a work base to provide a stable platform on which the graft can be treated...
65 GUDID devices
A mobile assembly of electrically-powered devices intended to provide a physician with both electromagnetic (EM) and optical tools to track manual surgical instruments and locate target anatomical structures with respect to pre-acquired images (e.g., CT/MRI...
59 GUDID devices
A stationary assembly of mains electricity (AC-powered) devices intended for the treatment of neurological, psychiatric and/or cognitive conditions (e.g., Alzheimer's disease, major depressive disorder, pain) through noninvasive magnetic stimulation of the ...
52 GUDID devices
A mobile assembly of electrically-powered devices intended to provide a physician with optical tools to track manual surgical instruments and locate anatomical structures with respect to pre-acquired images (e.g., CT/MRI scan) or real-time data [e.g., endos...
50 GUDID devices
A mobile (on wheels) assembly of mains electricity (AC-powered) devices intended for the treatment and/or diagnosis of neurological, psychiatric and/or cognitive conditions (e.g., Alzheimer's disease, major depressive disorder, pain) through noninvasive mag...
49 GUDID devices
An assembly of devices designed to provide the operator with a workstation for the preparation and pretensioning of a ligament and/or tendon graft prior to implantation. It typically consists of a work base to provide a stable platform on which the graft ca...