Robotic electrosurgical instrument, bipolar, reusable

47 GUDID devices

An electrosurgical device intended to be connected directly to the arm of a robotic surgical system to deliver electrosurgical current in a bipolar configuration (i.e., without a return electrode) from a generator directly to tissues for cutting/coagulation...

Robotic electrosurgical instrument, bipolar, single-use

10 GUDID devices

A electrosurgical device intended to be connected directly to the arm of a robotic surgical system to deliver electrosurgical current in a bipolar configuration (i.e., without a return electrode) from a generator directly to tissues for cutting/coagulation/...

Robotic electrosurgical instrument, bipolar, single-use

8 GUDID devices

A sterile electrosurgical device intended to be connected directly to the arm of a robotic surgical system to deliver electrosurgical current in a bipolar configuration (i.e., without a return electrode) from a generator directly to tissues for cutting/coag...

Percutaneous radio-frequency ablation probe, denervation, bipolar

5 GUDID devices

A semi-flexible, hand-held surgical instrument intended to be percutaneously introduced via a dedicated cannula [under x-ray, ultrasound (US) or other external image guidance] to deliver radio-frequency current, in a bipolar configuration, from a system gen...

Percutaneous radio-frequency ablation probe, tumour-ablation, bipolar

150 GUDID devices

A semi-flexible, hand-held surgical instrument intended to be percutaneously introduced via a dedicated cannula [under computed tomography (CT), magnetic resonance imaging (MRI), or ultrasound (US) guidance] to deliver radio-frequency current in a bipolar c...

Percutaneous electrosurgical probe, denervation, bipolar

5 GUDID devices

A sterile, semi-flexible, hand-held surgical instrument intended to be percutaneously introduced via a dedicated cannula [under x-ray, ultrasound (US) or other external image guidance] to deliver radio-frequency current, in a bipolar configuration, from a s...

Robotic electrosurgical instrument, bipolar/monopolar

3 GUDID devices

An electrosurgical device intended to be connected directly to the arm of a robotic surgical system to deliver electrosurgical current in both a bipolar and monopolar configuration from a generator directly to tissues for cutting/coagulation/ablation during...

Percutaneous radio-frequency ablation probe, denervation, bipolar

2 GUDID devices

A semi-flexible, hand-held surgical instrument intended to be percutaneously introduced via a dedicated cannula [under x-ray, ultrasound (US) or other external image guidance] to deliver radio-frequency current, in a bipolar configuration, from a system gen...

Endoscopic electrosurgical electrode, bipolar, single-use

1,007 GUDID devices

An invasive, distal component of an electrosurgical assembly intended to deliver electrosurgical current in a bipolar configuration (i.e., without a return electrode) to tissues for cutting/coagulation/ablation during endoscopic (e.g., laparoscopic, arthros...

Endoscopic electrosurgical electrode, bipolar, reusable

349 GUDID devices

An invasive, distal component of an electrosurgical assembly intended to deliver electrosurgical current in a bipolar configuration (i.e., without a return electrode) to tissues for cutting/coagulation/ablation during endoscopic (including laparoscopic, art...

Endoscopic electrosurgical handpiece/electrode, bipolar, reusable

6,456 GUDID devices

An electrosurgical device which consists of a handpiece with mechanical and/or electrical controls, and a bipolar electrode intended to deliver electrosurgical current from a system generator directly to tissues for cutting/coagulation/ablation during endos...

Endoscopic electrosurgical handpiece/electrode, bipolar, single-use

803 GUDID devices

A sterile electrosurgical device which consists of a handpiece with mechanical and/or electrical controls, and a bipolar electrode intended to deliver electrosurgical current from a system generator directly to tissues for cutting/coagulation/ablation durin...

Endoscopic electrosurgical handpiece/electrode, bipolar, reprocessed

611 GUDID devices

A sterile electrosurgical device which consists of a handpiece with mechanical and/or electrical controls, and a bipolar electrode intended to deliver electrosurgical current from a system generator directly to tissues for cutting/coagulation/ablation durin...

Endoscopic electrosurgical electrode, bipolar, reprocessed

99 GUDID devices

A sterile, invasive, distal component of an electrosurgical assembly intended to deliver electrosurgical current in a bipolar configuration (i.e., without a return electrode) to tissues for cutting/coagulation/ablation during endoscopic (e.g., laparoscopic,...

Open-surgery electrosurgical handpiece/electrode, bipolar, reusable

14,142 GUDID devices

A rigid combined electrosurgical handpiece and bipolar electrode, intended to deliver electrosurgical current from a system generator directly to tissues for cutting/coagulation during an open surgical procedure. It is available in a variety of forms (e.g.,...

Open-surgery electrosurgical handpiece/electrode, bipolar, single-use

2,513 GUDID devices

A sterile rigid combined electrosurgical handpiece and bipolar electrode, intended to deliver electrosurgical current from a system generator directly to tissues for cutting/coagulation during an open surgical procedure. It is available in a variety of form...

Bioimpedance navigation spinal needle

2 GUDID devices

A sterile, sharp bevel-edged, hollow tubular metal instrument designed to be used: 1) as a bipolar electrode for real-time bioimpedance-based prediction of the needle tip location; and 2) for lumbar puncture/intrathecal injection. The needle and an included...

Electrolytic-plasma electrosurgical system

53 GUDID devices

An assembly of devices intended to use radio-frequency (RF) alternating current in a bipolar configuration to excite electrolytes within a solution (typically saline) to create a focused, charged plasma sphere for cutting and coagulation of soft tissues dur...

Radio-frequency skin contouring system applicator, bipolar

21 GUDID devices

A bipolar handpiece that is part of a skin contouring system that uses radio-frequency (RF) energy to provide a capacitively coupled electrical connection for the transfer of radiated energy through a patient's skin in deep heat-mediated skin modification. ...

Ophthalmic electrosurgical probe

4 GUDID devices

A sterile, hand-held, ophthalmic surgical instrument intended to be introduced through the eye surface to deliver radio-frequency current, in a bipolar configuration, from a system generator directly to ocular tissues for blood coagulation and/or tissue adh...

Block-monitoring peripheral nerve electrical stimulation system

66 GUDID devices

An assembly of battery-powered devices designed to apply electrical stimuli to a peripheral nerve (e.g., the ulnar or lower extremity nerve) to assess the adequacy of neuromuscular block during surgery, and its reversal during the recovery period. The syste...

Diagnostic peripheral nerve electrical stimulation system

64 GUDID devices

An assembly of devices designed to apply electrical stimuli in one peripheral region of the body while the response is monitored in another peripheral region. It typically consists of external electrodes (e.g., hand-held bipolar or ring electrodes) or needl...

Cardiac radio-frequency ablation system catheter

438 GUDID devices

A sterile, flexible, steerable catheter intended to be used as part of a radio-frequency cardiac ablation system to apply radio-frequency alternating current to ablate areas of the endocardium of a beating heart in the treatment of cardiac arrhythmias; it i...

Cardiac mapping/radio-frequency ablation catheter, single-use

224 GUDID devices

A sterile, flexible, steerable catheter intended to be used as part of a cardiac mapping system and/or a radio-frequency cardiac ablation system to transmit electrical pacing stimuli to, and electrical responses from, the heart for electrophysiological (EP)...

Temporary cardiac pacing balloon catheter

124 GUDID devices

A sterile, flexible, balloon-tipped, tube designed to deliver temporary pacing stimuli to the heart; it may detect bioelectric signals from the heart. It is used in the atria and/or ventricles and has electrodes which are usually applied to the ventricles a...

Temporary cardiac pacing catheter

56 GUDID devices

A sterile, flexible tube designed to deliver temporary pacing stimuli to the heart; it may detect bioelectric signals from the heart. It is used in the atria and/or ventricles and has electrodes which are usually applied to the ventricles and connect to an ...

Endoscopic electrosurgical/ultrasonic surgical system instrument

34 GUDID devices

A hand-held, endoscopic device intended to be used as part of an electrosurgical/ultrasonic system to deliver both: 1) ultrasonic energy; and 2) bipolar electrosurgical current for fragmenting, cutting and coagulation of soft-tissues during endoscopic (e.g....

Plasma surgical system handpiece

34 GUDID devices

A hand-held instrument used with a plasma surgical system control unit to coagulate, cut, and/or vaporize/ablate tissue during open and/or laparoscopic surgery. Inert argon (Ar) gas is excited (ionized) in the instrument by a series of internal bipolar elec...

Radio-frequency skin surface treatment system applicator

31 GUDID devices

A handpiece component of a radio-frequency skin surface treatment system designed to be used by a healthcare professional to deliver bipolar radio-frequency (RF) energy to the skin surface for skin resurfacing. It is typically designed to deliver RF energy ...