386 GUDID devices
An electrical conductor located at one end of an appropriate flexible catheter (not included) which is inserted into the chambers of the heart in order for the electrode to detect the presence of certain indicators to measure cardiac output. The relayed sig...
5 GUDID devices
An electrical conductor located at one end of an appropriate flexible catheter (not included) which is inserted into the chambers of the heart in order for the electrode to detect the presence of certain indicators to measure cardiac output. The relayed sig...
4 GUDID devices
An insulated electrical conductor used to provide an electrical connection between a cardiac tissue ablation system generator and the operative ablative device (e.g., a dedicated cardiac tissue ablation system applicator or a catheter). Its length may also ...
5,684 GUDID devices
A sterile, invasive, electrical conductor that is temporarily placed (< 30 days) on the surface of the brain to stimulate the brain or to record the brain's electrical activity (with more precise localization than a scalp electrode). It is typically a serie...
3,064 GUDID devices
A non-sterile, noninvasive electrical conductor designed to conduct electrical signals, generated by a patient's heart, from the skin surface to an electrocardiograph (ECG) monitoring device, via an ECG lead wire (not included). It is typically a disk-like ...
2,704 GUDID devices
An invasive, monopolar, electrical conductor intended to be attached to an appropriate handle/handpiece (not included) to deliver electrosurgical current directly to tissues for cutting/coagulation during an open surgical procedure. It may be available in a...
1,786 GUDID devices
A non-sterile electrical conductor intended to be attached to a patient's skin (noninvasive) to provide therapeutic electrical stimuli through the body surface [e.g., transcutaneous electrical nerve stimulation (TENS), electrical muscle stimulation, cranial...
1,644 GUDID devices
An electrical conductor intended to be temporarily placed (< 30 days) beneath the surface of the brain to stimulate the brain or to record the brain's electrical activity (with more precise localization than a scalp electrode). It is typically a fine, flexi...
1,534 GUDID devices
An electrical conductor intended to be attached to a patient's skin (noninvasive) to provide therapeutic electrical stimuli through the body surface [e.g., transcutaneous electrical nerve stimulation (TENS), electrical muscle stimulation (EMS), cranial elec...
1,501 GUDID devices
A sterile, multi-purpose electrical conductor inserted beneath the dermal layer of a patient's skin to record/monitor electrical activity (biopotentials) for physiological measurements [typically electroencephalography (EEG), electromyography (EMG), and evo...
1,409 GUDID devices
An invasive, monopolar, electrical conductor intended to be attached to an electrosurgical handpiece (not included) to deliver electrosurgical current directly to tissues for cutting/coagulation during an open surgical procedure. It may be available in a va...
941 GUDID devices
A noninvasive electrical conductor designed to be attached to the scalp surface of a patient to transmit changes in the electrical potential of various areas of the brain for recording/monitoring by a connected parent device [i.e., an electroencephalograph ...
466 GUDID devices
A hand-held surgical instrument intended to function as an electrical conductor to locate a nerve during open surgery, and for diagnostic purposes [electromyography (EMG), cortical mapping], by delivering controlled electrical impulses to a specific body si...
407 GUDID devices
A dispersive conductor intended to be fastened to a patient and connected to an electrosurgical/radio-frequency ablation system generator, to allow return of electrical current from the patient to the generator during an electrosurgical procedure. It has a ...
339 GUDID devices
An electrical conductor designed to be attached to the skin surface of a patient outside of the hair line (i.e., non-scalp) to conduct electrical signals to/from a parent device for electrophysiological recording/monitoring [e.g., electromyography (EMG), ev...
327 GUDID devices
A non-sterile, electrical conductor designed to be attached to the skin surface of a patient outside of the hair line (i.e., non-scalp) to conduct electrical signals to a parent device for electrophysiological recording/monitoring [e.g., electromyography (E...
324 GUDID devices
An electrical conductor intended to be attached to a patient's skin (noninvasive) to provide therapeutic electrical stimuli through the body surface [e.g., transcutaneous electrical nerve stimulation (TENS), electrical muscle stimulation (EMS), cranial elec...
300 GUDID devices
A sterile, implantable flexible wire with an electrode, insulated with non-conductive material except at its ends, which serves as an electrical conductor to transmit pacing impulses from an implanted pulse generator to the heart; it is not intended to cond...
264 GUDID devices
A flexible wire with an electrode, insulated with non-conductive material except at its ends, that serves as an electrical conductor between the heart and an external temporary pacing/defibrillation device used to treat postoperative cardiac arrhythmias/car...
215 GUDID devices
A sterile, implantable flexible wire with an electrode, insulated with non-conductive material except at its ends, intended to function as an electrical conductor to transmit defibrillation impulses from an implanted cardioverter-defibrillator (ICD) [automa...
165 GUDID devices
The non-sterile external portion of a cochlear implant system [cochlear implant (CI)] that typically consists of a flexible and insulated electrical conductor with dedicated connectors designed to conduct electrical signals from the CI sound processor to th...
162 GUDID devices
An active conductor (e.g., blade or loop) that is attached to an electrocautery system handpiece or other surgical instrument (e.g., an endoscopic device) which is heated via the electrical current from the generator and used during surgical intervention to...
158 GUDID devices
A sterile, hand-held surgical instrument intended to function as an electrical conductor to locate a nerve during open surgery, and for diagnostic purposes [electromyography (EMG)], by delivering controlled electrical impulses to a specific body site for th...
157 GUDID devices
An electronic listening device designed to be inserted into a patient's oesophagus to listen to heart and breathe sounds, typically while the patient is under anaesthesia. Some types may also have a temperature sensor to monitor the patient's temperature. T...
151 GUDID devices
A noninvasive electrical conductor designed to conduct electrical signals, generated by a patient's heart, from the skin surface to an electrocardiograph (ECG) monitoring device, via an ECG lead wire (not included). It is typically a disk-like electrode tha...
140 GUDID devices
A non-sterile dispersive conductor intended to be fastened to a patient and connected to an electrosurgical/radio-frequency ablation system generator, to allow return of electrical current from the patient to the generator during an electrosurgical procedur...
139 GUDID devices
An external component of a cochlear implant (CI) or auditory brainstem implant system that typically consists of a flexible and insulated electrical conductor with dedicated connectors designed to conduct electrical signals from the sound processor to the c...
133 GUDID devices
A sterile, hand-held, manual, surgical instrument designed for percutaneous or mini-open transection of the transverse carpal ligament for median nerve decompression. It typically consists of a tubular fenestrated probe that contains a wire with a toothed c...
132 GUDID devices
An assembly of noninvasive devices intended to use electrocardiographic (ECG) data to assist guidance and positioning of a central venous catheter [e.g., peripherally-inserted central catheter (PICC), central venous catheter (CVC), haemodialysis catheter]. ...
117 GUDID devices
A non-sterile electrical conductor applied to a neonatal patient to transmit electrical signals from the body surface to a data measuring/display device (typicaly an electrocardiograph, patient monitor, or patient monitoring system) to produce an electrocar...