375 GUDID devices
A component of a dental power tool handpiece designed to connect between a dental power tool motor and an endpiece to transfer mechanical energy from the motor to the endpiece during a dental surgical procedure. It may be in the form of a torque multiplier,...
1 GUDID devices
A hand-held device which is a component of a line-powered (AC-powered) craniotomy system or multi-purpose line-powered surgical power tool system, intended to be used to rotate a cranial cutting tool (i.e., a drill bit, bur, trephine or perforator) in order...
371 GUDID devices
An assembly of devices designed to resect bones, tough tissues (e.g., cartilage, ligaments), and soft tissues during a surgical procedure; it is not dedicated to a specific clinical application. It includes a mains electricity (AC-powered) control unit whic...
343 GUDID devices
A mains electricity (AC-powered) component of a line-powered surgical/dental power tool system intended to step down the electrical power from the mains to supply the handpiece/motor (not included), and may also be intended to regulate some of the functions...
51 GUDID devices
An assembly of devices designed to resect bones and tough tissues (e.g., cartilage, ligaments) during a surgical procedure; it is not dedicated to a specific clinical application. It includes a pneumatically-powered control unit which controls output of nit...
48 GUDID devices
An assembly of devices designed to resect bones and tough tissues (e.g., cartilage, ligaments) during a surgical procedure; it is not dedicated to a specific clinical application. It includes a rechargeable battery pack/control unit which supplies low-volta...
27 GUDID devices
A pneumatically-powered (gas-powered) component of a surgical power tool system intended to regulate the gas pressure supplied to the pneumatic handpiece/motor (not included) and may also be intended to regulate some of the functions of the connected power ...
2 GUDID devices
A component of a multi-device tool designed for compression of a femoral neck fracture during the implantation of a fixation femoral neck, head nail, and/or screw. It consists of one of a variety of devices: a double threaded wire, a tubular housing instrum...
454 GUDID devices
An electrically-powered one-piece device or modular device collection designed to accept an endpiece(s) [e.g., drill bit, saw blade] for drilling, cutting, polishing, and/or inserting procedures involving bones and tough tissues during a dental surgical pro...
398 GUDID devices
A pneumatically-powered one-piece device or modular device collection designed to accept an endpiece(s) [e.g., drill bit, saw blade] for drilling, cutting, polishing, and/or inserting procedures involving bones and tough tissues during a dental surgical pro...
244 GUDID devices
A mobile assembly of mains electricity (AC-powered) devices intended to provide a physician with optical tools to track manual surgical instruments and locate target anatomical structures with respect to pre-acquired images (e.g., CT/MRI scan) or real-time ...
175 GUDID devices
An assembly of devices intended to provide a physician with an electromagnetic (EM) tool for image registration and/or tracking of manual surgical instruments typically with respect to pre-acquired images (e.g., CT/MRI scan) or real-time data [e.g., ultraso...
121 GUDID devices
A mobile assembly of electrically-powered devices intended to provide a physician with optical tools to track manual surgical instruments and locate anatomical structures with respect to pre-acquired images (e.g., CT/MRI scan) or real-time data [e.g., endos...
90 GUDID devices
An assembly of devices intended to provide a physician with an electromagnetic (EM) tool for image registration and/or tracking of manual surgical instruments with respect to pre-acquired images (e.g., CT/MRI scan) or real-time data [e.g., ultrasound (US)] ...
62 GUDID devices
A mobile assembly of electrically-powered devices intended to provide a physician with both electromagnetic (EM) and optical tools to track manual surgical instruments and locate target anatomical structures with respect to pre-acquired images (e.g., CT/MRI...
28 GUDID devices
A mobile assembly of electrically-powered devices intended to provide a physician with optical tools to track manual surgical instruments and locate anatomical structures with respect to pre-acquired images (e.g., CT/MRI scan) or real-time data [e.g., endos...
23 GUDID devices
A mobile assembly of mains electricity (AC-powered) devices intended to provide a physician with both electromagnetic (EM) and optical tools to track manual surgical instruments and locate target anatomical structures with respect to pre-acquired images (e....
15 GUDID devices
A collection of devices intended exclusively for professional use to collect a clinical specimen at the point-of-care for subsequent in vitro diagnostic investigation of sexually transmitted infections (STI) [e.g., Chlamydia trachomatis, Neisseria gonorrhoe...
7 GUDID devices
A sterile, long, thin, flexible tube designed to deliver and place a non-surgical implantable endobronchial valve, via the working channel of a bronchoscope, into the bronchial lumen of a lung segment. It typically includes a loader; a tool that is used to ...
6 GUDID devices
A implantable artificial substitute for the metacarpophalangeal (MCP) joint(s) of the hand (finger) which typically has been damaged by rheumatoid, degenerative, or traumatic arthritis. It consists of multiple components made of metal [e.g., cobalt-chrome (...
5 GUDID devices
A non-sterile, non-steerable, multi-luminal, flexible tube intended to function as a housing for a compatible flexible endoscope and endoscopic tool(s), to facilitate introduction of the endoscope, and provide independent working channels/insufflation ports...
2 GUDID devices
An implantable device designed to be transorally inserted during an endoscopic procedure to secure the stomach fundus to the oesophagus above the gastro-oesophageal junction to create a partial intraluminal fundoplication for the prevention of gastro-oesoph...
2 GUDID devices
A collection of devices intended to be used by a layperson in the home to collect a clinical specimen for subsequent in vitro diagnostic investigation of sexually transmitted infections (STI) [e.g., Chlamydia trachomatis, Neisseria gonorrhoeae, Trichomonas ...
1 GUDID devices
A hand-held, manual device intended to be used by a dental professional to adjust an intraoral implantable craniofacial bone distractor to lengthen the distractor, typically during a procedure involving expansion of the maxilla. It is intended to be used in...