TYLENOL Extra Strength / TYLENOL Precise Cooling Pain Relief
Acetaminophen, Lidocaine, Menthol
Acetaminophen, Lidocaine, Menthol
Lidocaine, Menthol
Lidocaine
Lidocaine
Camphor, Menthol
Lidocaine
20260216
20250930
20250225
20241126
20241113
20241113
2024-05-09
2024-05-09
2023-01-07
2023-01-07
2023-01-07
2023-01-07
2023-01-07
A sterile, invasive, electrical conductor that is temporarily placed (< 30 days) on the surface of the brain to stimulate the brain or to record the brain's electrical activity (with more precise localization than a scalp electrode). It is typically a serie...
An orthopaedic surgical instrument designed to resect bone (cut out part of the bone) and precisely shape a specific area of bone as it is advanced for the acceptance of a prosthetic implant, typically at or within a joint (e.g., condyle of knee, neck of hu...
An orthopaedic surgical instrument designed to resect (cut out part of the bone) and precisely shape a specific area of bone for the acceptance of a prosthetic implant, typically at or within a joint (e.g., condyle of knee, neck of humerus, olecranon of uln...
A hand-held manual ophthalmic surgical instrument designed to make precise incisions in the eye and surrounding tissues during ophthalmic surgery. It is typically designed as a one-piece instrument with a sharp, single-edged cutting blade at the distal tip ...
An assembly of devices that typically consists of a rigid frame, positioning and alignment components, workstation, and a calibrated guide mechanism for precisely positioning probes, other instruments, or implantable devices during neurosurgery. The system ...
An assembly of electromechanical devices used during orthopaedic computer assisted surgery (CAS) as a functional extension of the surgeon for precise procedural movement and placement (navigation) during the procedure (e.g., placement of a pedicle screw in ...
An electrical conductor intended to be temporarily placed (< 30 days) beneath the surface of the brain to stimulate the brain or to record the brain's electrical activity (with more precise localization than a scalp electrode). It is typically a fine, flexi...
An assembly of devices that typically consists of a rigid frame, positioning and alignment components, workstation, and a calibrated guide mechanism for precisely positioning probes, other instruments, or implantable devices during a surgical procedure of m...
A surgical jig-like device designed as a precision guide for the pre-drilling of orthopaedic screw holes into bone and for guiding an orthopaedic instrument into an implanted device, typically to treat long bones (e.g., femur, humerus, and tibia). It typica...
A manual instrument intended to be used to imprint, indent, and/or incise corneal tissue prior to an ophthalmic surgical procedure. It is typically made of high-grade stainless steel and includes a long slender handle with a distal end having characteristic...
An assembly of devices designed to generate and apply radio-frequency (RF) electrical current for heating via an electrode(s) in a precise location, at a controlled temperature, for focal ablation of non-cardiac tissues, including nerves, tumours, precancer...
A hand-held manual ophthalmic surgical instrument designed to make precise incisions in the eye and surrounding tissues during ophthalmic surgery. It is typically designed as a one-piece instrument with a sharp, single-edged cutting blade at the distal tip ...
An assembly of devices that typically consists of a rigid frame, positioning and alignment components, workstation, and a calibrated guide mechanism for precisely positioning probes, other instruments, or implantable devices during orthopaedic surgery. The ...
A device intended to be affixed to a patient's skull to enable precise localization of an area within the brain targeted for radiosurgical procedures (e.g., radiation treatment of a brain tumour). It is typically an assembly that includes a head ring or a h...
A sterile, hand-held manual ophthalmic surgical instrument designed to make precise incisions in the eye and surrounding tissues during ophthalmic surgery. It is typically designed as a one-piece instrument with a sharp, single-edged cutting blade at the di...
A shaft of metal, typically with a spiralled portion at the cutting end (a twist drill bit), intended to be attached to a motorized handpiece, or other power source, to create a precise round hole at the appropriate depth in teeth or bone of the oral cavity...
A sterile, hand-held manual surgical instrument designed exclusively for the precise scraping and/or excising of skin/dermal tissue (e.g., for treatment of superficial warts or wounds). It is available in a variety of shapes/sizes and has an appropriately-s...
A device designed to be attached to a suction system to control the degree of negative pressure (suction) applied in the evacuation of fluids, solids, or gases from the body during a neurosurgical procedure where the precise level of suction can be critical...
An orthopaedic surgical instrument intended to resect bone (cut out part of the bone) and precisely shape a specific area of bone to accept a prosthetic implant, typically at or within a joint (e.g., condyle of knee, neck of humerus, olecranon of ulna); som...
A collection of surgical instruments intended to cut a precise circular section of the cornea (corneal button) from stored cadaveric donor tissue for transplantation into a prepared patient. It typically consists of a small base plate, an extremely sharp an...
An assembly of electromechanical devices typically used during orthopaedic computer assisted surgery (CAS) as a functional extension of the surgeon for precise bone and soft-tissue modelling or soft-tissue removal (e.g., during a total knee joint arthroplas...
A mains electricity (AC-powered) device assembly in which input energy (e.g., flashlamp, diode laser) is used to excite a glass/crystal rod to emit a high-power laser beam, in which the frequency is doubled, intended to precisely cut, excise/vaporize, and c...
A flexible, form-shaped device designed to be placed over the nose and mouth to deliver a near-precise mixture of air and oxygen (O2) to a patient's airway without the use of a gas mixer. The device typically includes a variety of exchangeable inserts (the ...
A fixed or variable focal distance lasing device assembly designed to project a harmless beam (light pattern) onto a patient's skin or other alignment device. It is typically used to position and/or monitor the position of a patient during diagnostic imagin...
An orthopaedic surgical instrument designed to resect bone (cut out part of the bone) and precisely shape a specific area of bone as it is advanced for the acceptance of a prosthetic implant, typically at or within a joint (e.g., condyle of knee, neck of hu...
A sterile, orthopaedic, surgical instrument designed to resect (cut out part of the bone) and precisely shape a specific area of bone for the acceptance of a prosthetic implant, typically at or within a joint (e.g., condyle of knee, neck of humerus, olecran...
A slender, rod-like, hand-held manual surgical instrument intended for use during image-guided surgery (e.g., neurosurgical or orthopaedic surgery procedures) to accurately position implantable devices (e.g., shunts), or to correlate the position of its tip...
A hollow, cylindrical, curved device designed as an internal, independent component of a metal tracheostomy tube. It is made of metal [e.g., high-grade stainless steel and/or silver (Ag) or silver plated brass] or plastic and has precise dimensions allowing...
A mains electricity (AC-powered) device, which may include internal rechargeable batteries, intended for the delivery of precise amounts of nitric oxide (NO), also known as nitrogen monoxide, to the respiratory tract of neonate, paediatric, and adult patien...
An assembly of electromechanical devices designed to be used during computer assisted surgery (CAS) as a functional extension of the surgeon for precise bone and soft-tissue modelling or soft-tissue removal (e.g., during a total knee joint arthroplasty (TKA...