6 GUDID devices
A connecting device designed to allow the attachment of an ophthalmic surgical instrument tip to an ophthalmic surgical instrument handle. It is typically in the form of a small, stainless steel, circular adaptor with a threaded interface that attaches to a...
203 GUDID devices
A male connecting device used to connect to a medical gas pipeline system or other gas source allowing a user to rapidly connect and disconnect nitrous oxide (N2O) dependent devices to the N2O supply. It has safety features such as a specific mechanical mat...
108 GUDID devices
A male connecting device intended to be used to connect to a medical gas/vacuum pipeline system or other vacuum connection allowing a user to rapidly connect and disconnect vacuum dependent devices to the vacuum source. It has safety features such as a spec...
105 GUDID devices
A male connecting device used to connect to a medical gas pipeline system or other gas source allowing a user to rapidly connect and disconnect oxygen (O2) dependent devices to the O2 supply. It has safety features such as a specific mechanical mating patte...
71 GUDID devices
A male connecting device used to connect to a medical gas pipeline system or other gas source allowing a user to rapidly connect and disconnect medical air dependent devices to the medical air supply. It has safety features such as a specific mechanical mat...
42 GUDID devices
A male connecting device used to connect to a medical gas pipeline system or other gas source allowing a user to rapidly connect and disconnect nitrogen (N2) dependent devices to the nitrogen supply. It has safety features such as a specific mechanical mati...
18 GUDID devices
A male connecting device used to connect to the anaesthetic gas scavenging (AGS) terminal unit of a medical gas pipeline system or a female AGS connector allowing a user to rapidly connect and disconnect an anaesthetic gas scavenging system (AGSS) for the c...
1 GUDID devices
A male connecting device used to connect to a medical gas pipeline system or other gas source allowing a user to rapidly connect and disconnect helium/oxygen dependent devices to a mixture of 79% helium (He) and 21% oxygen (O2) supply. It has safety feature...
159 GUDID devices
A female connecting device used to accept a male oxygen (O2) connector to connect two devices together to provide a continuous passageway for the delivery of O2. It has safety features such as a specific mechanical mating pattern, colour coding and a dedica...
118 GUDID devices
A female connecting device used to accept a male nitrogen (N2) connector to connect two devices together to provide a continuous passageway for the delivery of nitrogen. It has safety features such as a specific mechanical mating pattern, colour coding and ...
71 GUDID devices
A female connecting device used to accept a male vacuum connector to connect two devices together to provide a continuous passageway to the vacuum source. It has safety features such as a specific mechanical mating pattern, colour coding and a dedicated tub...
60 GUDID devices
A female connecting device used to accept a male medical air connector to connect two devices together to provide a continuous passageway for the delivery of medical air. It has safety features such as a specific mechanical mating pattern, colour coding and...
12 GUDID devices
A female connecting device used to accept a male nitrous oxide (N2O) connector to connect two devices together to provide a continuous passageway for the delivery of N2O. It has safety features such as a specific mechanical mating pattern, colour coding and...
7 GUDID devices
A female connecting device used to accept a male anaesthetic gas scavenging (AGS) connector to connect two devices together to provide a continuous passageway for the controlled evacuation of exhaust anaesthesia gases. It has safety features such as a speci...
5 GUDID devices
A female connecting device used to accept a male nitrous oxide/oxygen connector to connect two devices together to provide a continuous passageway for the delivery of a mixture of 50% nitrous oxide (N2O) and 50% oxygen (O2). It has safety features such as a...
1 GUDID devices
A female connecting device used to accept a male helium/oxygen connector to connect two devices together to provide a continuous passageway for the delivery of a mixture of 79% helium (He) and 21% oxygen (O2). It has safety features such as a specific mecha...
165 GUDID devices
An electrically-powered one-piece device or modular device collection designed to accept an endpiece(s) [e.g., drill bit, saw blade, bur] for drilling, cutting, and/or inserting procedures involving bones and tough tissues during a surgical procedure; it is...
100 GUDID devices
An electrically-powered one-piece device or modular device collection designed to accept an endpiece(s) [e.g., drill bit, saw blade, bur] for drilling, cutting, and/or inserting procedures involving bones and tough tissues during a non-dental surgical proce...
61 GUDID devices
A pneumatically-powered one-piece device or modular device collection designed to accept an endpiece(s) [e.g., drill bit, saw blade, bur] for drilling, cutting, and/or inserting procedures involving bones and tough tissues during a non-dental surgical proce...
42 GUDID devices
A reduction valve designed to lower high and variable gas pressure in a pipeline intended for surgical applications (e.g., to drive surgical power tools) to a lower and constant working pressure, typically 3 - 12 bar. It consists of a housing containing a s...
24 GUDID devices
An electrically-powered one-piece device or modular device collection designed to accept an endpiece(s) [e.g., drill bit, saw blade, bur] for drilling, cutting, and/or inserting procedures involving bones and tough tissues during a non-dental surgical proce...
3,272 GUDID devices
A device intended to connect to a surgical power tool system motor [it is locked and held in a collet or quick coupling and not simply gripped in a drill chuck (Jacobs chuck)] to convert the non-dedicated mechanical energy provided by the motor to a dedicat...
3,211 GUDID devices
A device intended to connect to a surgical power tool system motor [it is locked and held in a collet or quick coupling and not simply gripped in a drill chuck (Jacobs chuck)] to convert the non-dedicated mechanical energy provided by the motor to a dedicat...
1,340 GUDID devices
A flexible, cylindrical device that typically connects a contrast imaging syringe to a patient cannula for the conduction of contrast media and flushing fluids to a patient during diagnostic radiographic procedures [e.g., angiography or computed tomography ...
756 GUDID devices
A device intended to connect to a surgical power tool system motor [it is locked and held in a collet or quick coupling and not simply gripped in a drill chuck (Jacobs chuck)] to convert the non-dedicated mechanical energy provided by the motor to a dedicat...
178 GUDID devices
A device intended to connect to a surgical power tool system motor [it is locked and held in a collet or quick coupling and not simply gripped in a drill chuck (Jacobs chuck)] to convert the non-dedicated mechanical energy provided by the motor to a dedicat...
154 GUDID devices
A replaceable component of a medical or dental diagnostic, or therapeutic x-ray system consisting of a tube (a glass envelope enclosing a filament, anode, cathode under vacuum, and an interface for an electrical connection) designed to convert an input of e...
109 GUDID devices
A device intended to connect to a surgical power tool system motor [it is locked and held in a collet or quick coupling and not simply gripped in a drill chuck (Jacobs chuck)] to convert the non-dedicated mechanical energy provided by the motor to a dedicat...
71 GUDID devices
A device intended to connect to a surgical power tool system motor [it is locked and held in a collet or quick coupling and not simply gripped in a drill chuck (Jacobs chuck)] to convert the non-dedicated mechanical energy provided by the motor to a dedicat...
60 GUDID devices
A small component of a powered reaming assembly intended to connect to a surgical power tool system motor [it is locked and held in a collet or quick coupling and not simply gripped in a drill chuck (Jacobs chuck)] to convert the non-dedicated mechanical en...