CAPTION HEALTH

Matched from indexed company URL: Caption Health, Inc.

FDA Registration(s)#

Registration, FEI, Name table
RegistrationFEINameStatusInitial importerExpiration yearAddress
30166650373016665037CAPTION HEALTH1N2020-04-252000 Sierra Point Parkway 8th Floor Brisbane CA US 94005

GUDID Contact Samples#

Sampled from matched GUDID device records for this company; this is not an exhaustive company contact directory.

Source GUDID, Product, Phone table
Source GUDIDProductPhoneEmail
00860003586303Caption AI (Caption Guidance + Caption Interpretation) - The Caption Guidance software is indicated for use in two-dimensional transthoracic echocardiography (2DTTE) for adult patients, specifically in the acquisition of the following standard views: Parasternal Long-Axis (PLAX), Parasternal Short-Axis at the Aortic Valve (PSAX-AV), Parasternal Short-Axis at the Mitral Valve (PSAX-MV), Parasternal Short-Axis at the Papillary Muscle (PSAX-PM), Apical 4-Chamber (AP4), Apical 5- Chamber (AP5), Apical 2-Chamber (AP2), Apical 3-Chamber (AP3), Subcostal 4-Chamber (SubC4), and Subcostal Inferior Vena Cava (SC-IVC). The Caption Interpretation Automated Ejection Fraction software is used to process previously acquired transthoracic cardiac ultrasound images, to store images, and to manipulate and make measurements on images using an ultrasound device, personal computer, or a compatible DICOM-compliant PACS system in order to provide automated estimation of left ventricular ejection fraction. This measurement can be used to assist the clinician in a cardiac evaluation. The Caption Interpretation Automated Ejection Fraction Software is indicated for use in adult patients.(855) 506-4357support@captionhealth.com
00860003586310Caption AI (Caption Guidance + Caption Interpretation) - Caption AI (Caption Guidance + Caption Interpretation) on portable handheld ultrasound. The Caption Guidance software is indicated for use in two-dimensional transthoracic echocardiography (2DTTE) for adult patients, specifically in the acquisition of the following standard views: Parasternal Long-Axis (PLAX), Parasternal Short-Axis at the Aortic Valve (PSAX-AV), Parasternal Short-Axis at the Mitral Valve (PSAX-MV), Parasternal Short-Axis at the Papillary Muscle (PSAX-PM), Apical 4-Chamber (AP4), Apical 5- Chamber (AP5), Apical 2-Chamber (AP2), Apical 3-Chamber (AP3), Subcostal 4-Chamber (SubC4), and Subcostal Inferior Vena Cava (SC-IVC). The Caption Interpretation Automated Ejection Fraction software is used to process previously acquired transthoracic cardiac ultrasound images, to store images, and to manipulate and make measurements on images using an ultrasound device, personal computer, or a compatible DICOM-compliant PACS system in order to provide automated estimation of left ventricular ejection fraction. This measurement can be used to assist the clinician in a cardiac evaluation. The Caption Interpretation Automated Ejection Fraction Software is indicated for use in adult patients.(855) 506-4357support@captionhealth.com

Registered Device Listings#

Registration key, Listing key, Premarket submission table
Registration keyListing keyPremarket submissionDeviceProduct codeDecision date
2391941964706319K173780EchoMD Automated Ejection Fraction SoftwareLLZ2018-06-14
2391941678380003DEN190040Caption GuidanceQJU2020-02-07

Product Codes Associated With Registrations#

Product code, Registration listing records, Latest decision table
Product codeRegistration listing recordsLatest decision
QJU12020-02-07
LLZ12018-06-14

PMN#

GUDID#

Caption Guidance - The Caption Guidance software is intended to assist medical professionals in the acquisition of cardiac ultrasound images. Caption Guidance software is an accessory to compatible general purpose diagnostic ultrasound systems. Caption Guidance software is indicated for use in two-dimensional transthoracic echocardiography (2D-TTE) for adult patients, specifically in the acquisition of the following standard views: Parasternal Long-Axis (PLAX), Parasternal Short-Axis at the Aortic Valve (PSAX-AV), Parasternal Short-Axis at the Mitral Valve (PSAX-MV), Parasternal Short-Axis at the Papillary Muscle (PSAX-PM), Apical 4-Chamber (AP4), Apical 5-Chamber (AP5), Apical 2-Chamber (AP2), Apical 3-Chamber (AP3), Subcostal 4-Chamber (SubC4), and Subcostal Inferior Vena Cava (SC-IVC).

CAPTION HEALTH, INC.

2023-09-30

Caption AI (Caption Guidance + Caption Interpretation) - Caption AI (Caption Guidance + Caption Interpretation) on portable handheld ultrasound. The Caption Guidance software is indicated for use in two-dimensional transthoracic echocardiography (2DTTE) for adult patients, specifically in the acquisition of the following standard views: Parasternal Long-Axis (PLAX), Parasternal Short-Axis at the Aortic Valve (PSAX-AV), Parasternal Short-Axis at the Mitral Valve (PSAX-MV), Parasternal Short-Axis at the Papillary Muscle (PSAX-PM), Apical 4-Chamber (AP4), Apical 5- Chamber (AP5), Apical 2-Chamber (AP2), Apical 3-Chamber (AP3), Subcostal 4-Chamber (SubC4), and Subcostal Inferior Vena Cava (SC-IVC). The Caption Interpretation Automated Ejection Fraction software is used to process previously acquired transthoracic cardiac ultrasound images, to store images, and to manipulate and make measurements on images using an ultrasound device, personal computer, or a compatible DICOM-compliant PACS system in order to provide automated estimation of left ventricular ejection fraction. This measurement can be used to assist the clinician in a cardiac evaluation. The Caption Interpretation Automated Ejection Fraction Software is indicated for use in adult patients.

CAPTION HEALTH, INC.

2022-03-15

Caption AI (Caption Guidance + Caption Interpretation) - The Caption Guidance software is indicated for use in two-dimensional transthoracic echocardiography (2DTTE) for adult patients, specifically in the acquisition of the following standard views: Parasternal Long-Axis (PLAX), Parasternal Short-Axis at the Aortic Valve (PSAX-AV), Parasternal Short-Axis at the Mitral Valve (PSAX-MV), Parasternal Short-Axis at the Papillary Muscle (PSAX-PM), Apical 4-Chamber (AP4), Apical 5- Chamber (AP5), Apical 2-Chamber (AP2), Apical 3-Chamber (AP3), Subcostal 4-Chamber (SubC4), and Subcostal Inferior Vena Cava (SC-IVC). The Caption Interpretation Automated Ejection Fraction software is used to process previously acquired transthoracic cardiac ultrasound images, to store images, and to manipulate and make measurements on images using an ultrasound device, personal computer, or a compatible DICOM-compliant PACS system in order to provide automated estimation of left ventricular ejection fraction. This measurement can be used to assist the clinician in a cardiac evaluation. The Caption Interpretation Automated Ejection Fraction Software is indicated for use in adult patients.

CAPTION HEALTH, INC.

2020-06-05