DIRECTED SYSTEMS LTD

FDA Registration(s)#

Registration, FEI, Name table
RegistrationFEINameStatusInitial importerExpiration yearAddress
30165853663016585366DIRECTED SYSTEMS LTD1N2026-01-0147-51 Norfolk Street Cambridge Cambridgeshire GB CB1 2LD

Registered Device Listings#

Registration key, Listing key, Premarket submission table
Registration keyListing keyPremarket submissionDeviceProduct codeDecision date
2389231682456103K212529Hypotension Decision Assist Model HDA-OR2DXG2021-11-23
2389231264378081K190955Hypotension Decision AssistDXG2019-11-27

Product Codes Associated With Registrations#

Product code, Registration listing records, Latest decision table
Product codeRegistration listing recordsLatest decision
DXG22021-11-23

PMN#

GUDID#

Hypotension Decision Assist (HDA) - Hypotension Decision Assist (HDA) is a clinical decision support Software as a Medical Device (SaMD) that is installed upon a medically-rated touch-screen computer. HDA connects to a multi-parameter patient monitor supplied by other manufacturers, from which it acquires vital signs data continuously including the arterial blood pressure waveform and cardiovascular-related numeric parameters.HDA continually processes this data to display, in graphical charts and numeric format, vital signs data and derived variables including mean arterial pressure (MAP), heart rate, systolic and diastolic blood pressure, cardiac output and systemic vascular resistance. HDA compares MAP to user set targets to indicate when MAP is above or below the target range. It allows the user to mark the administration of vasopressors and volume challenges to the MAP trend.

DIRECTED SYSTEMS LIMITED

2020-06-22

Hypotension Decision Assist (HDA) - Hypotension Decision Assist HDA-OR2 is a clinical decision support Software as a Medical Device (SaMD) that is installed upon amedically-rated touch-screen tablet computer. HDA-OR2 connects to a multi-parameter patient monitor supplied by other manufacturers, fromwhich it acquires vital signs data continuously including the arterial blood pressure waveform and cardiovascular-related numericparameters. HDA-OR2 continually processes this data to display, in graphical charts and numeric format, vital signs data and derivedvariables including mean arterial pressure (MAP), heart rate, systolic and diastolic blood pressure, cardiac output and systemicvascular resistance. HDA-OR2 compares MAP to user set targets to indicate when MAP is above or below the target range. It allowsthe user to mark the administration of vasopressors and volume challenges to the MAP trend.

DIRECTED SYSTEMS LIMITED

2022-01-04